Stent kryty w wewnątrznaczyniowym leczeniu zwężeń tętnic szyjnych: możliwość zastosowania, częstość powodzeń technicznych i częstość nawrotów zwężeń

2007
journal article
article
dc.abstract.enBackground: To assess the feasibility, technical success and the rate of in-stent restenosis of Carotid Artery Stenting (CAS) using a covered self-expanding stent. Material and methods: Fifty four (54) patients aged 65.75 ± 9.37 years (mean ± standard deviation) were enrolled in an open prospective clinical observation of filter-protected Carotid Artery Stenting (CAS) using a self-expanding covered stent. Altogether 56 arteries were treated. The feasibility of covered stent implantation, the technical success and the restenosis rate during a mean 16.5 (a range of 3-24) months follow-up were assessed. A high resolution color coded ultrasound was used to detect restenosis. Results: The stents were implanted successfully and good angiographic results were obtained in 53 patients and 55 arteries. In 2 cases two covered stents had to be implanted because of an initially incomplete coverage of the target lesions. There was one acute thrombosis of the internal carotid artery and two early in-stent restenoses due to lesion recoil. One late stenosis was seen at a 1 year follow-up. The patient was successfully treated with another CAS with neuroprotection. One total occlusion of a stent was detected 24 months after the CAS. Altogether the restenosis rate was 7.1%. Conclusions: Carotid artery stenosis can be successfully treated with a covered self-expanding stent with a low restenosis rate at a mean of 16.5 months. Randomized controlled trials comparing the safety of CAS using covered stents vs. bare metal stents seem justified.pl
dc.abstract.plWstęp: Celem niniejszej pracy była ocena możliwości zastosowania, częstości technicznego powodzenia zabiegu oraz częstości restenozy w stencie po zabiegu wszczepienia stentu krytego do tętnicy szyjnej wewnętrznej (CAS, carotid artery stenting). Materiał i metody: Do otwartej prospektywnej obserwacji klinicznej oceniającej przydatność stentu pokrywanego SYMBIOT stosowanego w przezskórnym poszerzaniu tętnic szyjnych w osłonie filtru przeciwzatorowego włączono 54 pacjentów w wieku 65,8 ± 9,4 (średnia ± odchylenie standardowe). Łącznie zabiegi wykonano na 56 tętnicach. Ocenie poddano: możliwość wprowadzenia stentu w obręb zwężenia, techniczne powodzenie zabiegu poszerzania tętnicy szyjnej oraz częstość restenozy w trakcie obserwacji trwającej średnio 16,5 miesiąca (przedział od 3–24). Do oceny restenozy wykorzystano kolorową ultrasonografię doplerowską o wysokiej rozdzielczości. Wyniki: Stent udało się wszczepić z powodzeniem u wszystkich chorych, a dobry efekt angiograficzny uzyskano u 53 pacjentów (55 tętnic). W 2 przypadkach konieczne było wszczepienie 2 stentów z uwagi na niepełne pokrycie blaszki miażdżycowej przez pierwszy stent. Wystąpiła jedna ostra zakrzepica w stencie oraz 2 wczesne restenozy w mechanizmie elastycznego odbicia. U jednego chorego doszło po roku do późnej restenozy - chory ten przeszedł z powodzeniem kolejną angioplastykę szyjną ze wszczepieniem stentu w osłonie filtru przeciwzatorowego. Jeden przypadek pełnej okluzji stentu wystąpił po 24. miesiącach od daty zabiegu. W całości odsetek restenozy wynosił 7,1%. Wnioski: Zwężenie tętnicy szyjnej wewnętrznej można z powodzeniem leczyć za pomocą samorozprężalnego stentu krytego; częstość restenozy w obserwacji trwającej średnio 16,5 miesiąca jest niska. Wydaje się, że warto przeprowadzić kontrolowane, randomizowane, prospektywne badanie porównujące bezpieczeństwo stentu krytego i metalowych stentów niepokrywanych w przezskórnym leczeniu zwężeń tętnic szyjnych.pl
dc.affiliationWydział Lekarski : Klinika Alergii i Immunologiipl
dc.affiliationWydział Lekarski : Klinika Angiologiipl
dc.contributor.authorKrzanowski, Marekpl
dc.contributor.authorBodzoń, Wojciechpl
dc.contributor.authorSłowik, Lidiapl
dc.contributor.authorNiżankowski, Rafał - 132990 pl
dc.contributor.authorSzczeklik, Andrzej - 133558 pl
dc.date.accession2020-10-15pl
dc.date.accessioned2020-10-15T08:02:33Z
dc.date.available2020-10-15T08:02:33Z
dc.date.issued2007pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.number2pl
dc.description.physical61-68pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume9pl
dc.identifier.eissn1644-3349pl
dc.identifier.issn1507-5524pl
dc.identifier.projectROD UJ / OPpl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/248047
dc.identifier.weblinkhttps://journals.viamedica.pl/chirurgia_polska/article/view/28863pl
dc.languagepolpl
dc.language.containerpolpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa*
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl*
dc.share.typeotwarte czasopismo
dc.subject.encarotid arterypl
dc.subject.enstenosispl
dc.subject.enstentpl
dc.subject.enmicroembolismpl
dc.subject.encovered stentpl
dc.subject.enself-expanding stentpl
dc.subject.pltętnica szyjna wewnętrznapl
dc.subject.plzwężeniepl
dc.subject.plstentpl
dc.subject.plmikrozatorypl
dc.subject.plstent pokrywanypl
dc.subject.plstent samorozprężalnypl
dc.subtypeArticlepl
dc.titleStent kryty w wewnątrznaczyniowym leczeniu zwężeń tętnic szyjnych: możliwość zastosowania, częstość powodzeń technicznych i częstość nawrotów zwężeńpl
dc.title.alternativeCovered self-expanding stent for endovascular treatment of carotid artery stenosis: feasibility, technical success and restenosis ratepl
dc.title.journalChirurgia Polskapl
dc.typeJournalArticlepl
dspace.entity.typePublication
dc.abstract.enpl
Background: To assess the feasibility, technical success and the rate of in-stent restenosis of Carotid Artery Stenting (CAS) using a covered self-expanding stent. Material and methods: Fifty four (54) patients aged 65.75 ± 9.37 years (mean ± standard deviation) were enrolled in an open prospective clinical observation of filter-protected Carotid Artery Stenting (CAS) using a self-expanding covered stent. Altogether 56 arteries were treated. The feasibility of covered stent implantation, the technical success and the restenosis rate during a mean 16.5 (a range of 3-24) months follow-up were assessed. A high resolution color coded ultrasound was used to detect restenosis. Results: The stents were implanted successfully and good angiographic results were obtained in 53 patients and 55 arteries. In 2 cases two covered stents had to be implanted because of an initially incomplete coverage of the target lesions. There was one acute thrombosis of the internal carotid artery and two early in-stent restenoses due to lesion recoil. One late stenosis was seen at a 1 year follow-up. The patient was successfully treated with another CAS with neuroprotection. One total occlusion of a stent was detected 24 months after the CAS. Altogether the restenosis rate was 7.1%. Conclusions: Carotid artery stenosis can be successfully treated with a covered self-expanding stent with a low restenosis rate at a mean of 16.5 months. Randomized controlled trials comparing the safety of CAS using covered stents vs. bare metal stents seem justified.
dc.abstract.plpl
Wstęp: Celem niniejszej pracy była ocena możliwości zastosowania, częstości technicznego powodzenia zabiegu oraz częstości restenozy w stencie po zabiegu wszczepienia stentu krytego do tętnicy szyjnej wewnętrznej (CAS, carotid artery stenting). Materiał i metody: Do otwartej prospektywnej obserwacji klinicznej oceniającej przydatność stentu pokrywanego SYMBIOT stosowanego w przezskórnym poszerzaniu tętnic szyjnych w osłonie filtru przeciwzatorowego włączono 54 pacjentów w wieku 65,8 ± 9,4 (średnia ± odchylenie standardowe). Łącznie zabiegi wykonano na 56 tętnicach. Ocenie poddano: możliwość wprowadzenia stentu w obręb zwężenia, techniczne powodzenie zabiegu poszerzania tętnicy szyjnej oraz częstość restenozy w trakcie obserwacji trwającej średnio 16,5 miesiąca (przedział od 3–24). Do oceny restenozy wykorzystano kolorową ultrasonografię doplerowską o wysokiej rozdzielczości. Wyniki: Stent udało się wszczepić z powodzeniem u wszystkich chorych, a dobry efekt angiograficzny uzyskano u 53 pacjentów (55 tętnic). W 2 przypadkach konieczne było wszczepienie 2 stentów z uwagi na niepełne pokrycie blaszki miażdżycowej przez pierwszy stent. Wystąpiła jedna ostra zakrzepica w stencie oraz 2 wczesne restenozy w mechanizmie elastycznego odbicia. U jednego chorego doszło po roku do późnej restenozy - chory ten przeszedł z powodzeniem kolejną angioplastykę szyjną ze wszczepieniem stentu w osłonie filtru przeciwzatorowego. Jeden przypadek pełnej okluzji stentu wystąpił po 24. miesiącach od daty zabiegu. W całości odsetek restenozy wynosił 7,1%. Wnioski: Zwężenie tętnicy szyjnej wewnętrznej można z powodzeniem leczyć za pomocą samorozprężalnego stentu krytego; częstość restenozy w obserwacji trwającej średnio 16,5 miesiąca jest niska. Wydaje się, że warto przeprowadzić kontrolowane, randomizowane, prospektywne badanie porównujące bezpieczeństwo stentu krytego i metalowych stentów niepokrywanych w przezskórnym leczeniu zwężeń tętnic szyjnych.
dc.affiliationpl
Wydział Lekarski : Klinika Alergii i Immunologii
dc.affiliationpl
Wydział Lekarski : Klinika Angiologii
dc.contributor.authorpl
Krzanowski, Marek
dc.contributor.authorpl
Bodzoń, Wojciech
dc.contributor.authorpl
Słowik, Lidia
dc.contributor.authorpl
Niżankowski, Rafał - 132990
dc.contributor.authorpl
Szczeklik, Andrzej - 133558
dc.date.accessionpl
2020-10-15
dc.date.accessioned
2020-10-15T08:02:33Z
dc.date.available
2020-10-15T08:02:33Z
dc.date.issuedpl
2007
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.numberpl
2
dc.description.physicalpl
61-68
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
9
dc.identifier.eissnpl
1644-3349
dc.identifier.issnpl
1507-5524
dc.identifier.projectpl
ROD UJ / OP
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/248047
dc.identifier.weblinkpl
https://journals.viamedica.pl/chirurgia_polska/article/view/28863
dc.languagepl
pol
dc.language.containerpl
pol
dc.rights*
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa
dc.rights.licence
CC-BY-NC-ND
dc.rights.uri*
http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl
dc.share.type
otwarte czasopismo
dc.subject.enpl
carotid artery
dc.subject.enpl
stenosis
dc.subject.enpl
stent
dc.subject.enpl
microembolism
dc.subject.enpl
covered stent
dc.subject.enpl
self-expanding stent
dc.subject.plpl
tętnica szyjna wewnętrzna
dc.subject.plpl
zwężenie
dc.subject.plpl
stent
dc.subject.plpl
mikrozatory
dc.subject.plpl
stent pokrywany
dc.subject.plpl
stent samorozprężalny
dc.subtypepl
Article
dc.titlepl
Stent kryty w wewnątrznaczyniowym leczeniu zwężeń tętnic szyjnych: możliwość zastosowania, częstość powodzeń technicznych i częstość nawrotów zwężeń
dc.title.alternativepl
Covered self-expanding stent for endovascular treatment of carotid artery stenosis: feasibility, technical success and restenosis rate
dc.title.journalpl
Chirurgia Polska
dc.typepl
JournalArticle
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
72
Views per month
Views per city
Warsaw
10
Szczecin
5
Poznan
4
Wroclaw
4
Ashburn
2
Bühl
2
Prudnik
2
Bydgoszcz
1
Dublin
1
Hoensbroek
1
Downloads
szczeklik_nizankowski_et-al_stent_kryty_w_wewnatrznaczyniowym_leczeniu_2007.pdf
6
szczeklik_nizankowski_et-al_stent_kryty_w_wewnatrznaczyniowym_leczeniu_2007.odt
2