Safety, feasibility, and effectiveness of a CT-guided transthoracic lung and pleural biopsy : a single-centre experience with own low-dose protocol

2023
journal article
article
1
dc.abstract.enPurpose: To assess the efficacy and safety of a low-dose, computed tomography (CT)-guided transthoracic biopsy of lung and pleural lesions. Material and methods: A total of 135 low-dose, CT-guided transthoracic lung and pleural lesions biopsies were performed. A cutting needle was utilized in 124 cases, and fine needle aspiration biopsy was performed in 14 cases. In all cases, 14- to 22-gauge biopsy needles were used. Results: Diagnostic material was obtained in 111 (82.2%) patients. In 97 (71.8%) cases neoplastic lesions were found, predominantly adenocarcinoma and non-small cell carcinoma. In 14 (12.6%) cases non atypical cells were reported. Biopsy failed to obtain material suitable for histopathological examination in 24 (17.7%) cases. Complications occurred in 31 patients, including pneumothorax in 28 patients and haematoma in 3 cases. Conclusions: Based on the obtained results, it can be stated that low-dose, CT-guided transthoracic biopsy of lung and pleural tissues is an accurate and safe procedure. Also, it is linked to a low risk of complications such as a small pneumothorax.
dc.contributor.authorGuzinski, Maciej
dc.contributor.authorPuła, Michał
dc.contributor.authorZdanowicz, Agata
dc.contributor.authorKacała, Arkadiusz
dc.contributor.authorDudek, Krzysztof
dc.contributor.authorLipiński, Artur
dc.contributor.authorSąsiadek, Marek
dc.date.accessioned2024-07-25T09:31:09Z
dc.date.available2024-07-25T09:31:09Z
dc.date.issued2023
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. e550-e551
dc.description.physicale546-e551
dc.description.versionostateczna wersja wydawcy
dc.description.volume88
dc.identifier.doi10.5114/pjr.2023.133309
dc.identifier.issn1733-134X
dc.identifier.urihttps://ruj.uj.edu.pl/handle/item/389441
dc.languageeng
dc.language.containereng
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl
dc.share.typeotwarte czasopismo
dc.subject.enCT-guided biopsy
dc.subject.enlow-dose
dc.subject.enlung biopsy
dc.subject.enpneumothorax
dc.subject.enhaematoma
dc.subject.enpleural biopsy
dc.subtypeArticle
dc.titleSafety, feasibility, and effectiveness of a CT-guided transthoracic lung and pleural biopsy : a single-centre experience with own low-dose protocol
dc.title.journalPolish Journal of Radiology
dc.typeJournalArticle
dspace.entity.typePublicationen
dc.abstract.en
Purpose: To assess the efficacy and safety of a low-dose, computed tomography (CT)-guided transthoracic biopsy of lung and pleural lesions. Material and methods: A total of 135 low-dose, CT-guided transthoracic lung and pleural lesions biopsies were performed. A cutting needle was utilized in 124 cases, and fine needle aspiration biopsy was performed in 14 cases. In all cases, 14- to 22-gauge biopsy needles were used. Results: Diagnostic material was obtained in 111 (82.2%) patients. In 97 (71.8%) cases neoplastic lesions were found, predominantly adenocarcinoma and non-small cell carcinoma. In 14 (12.6%) cases non atypical cells were reported. Biopsy failed to obtain material suitable for histopathological examination in 24 (17.7%) cases. Complications occurred in 31 patients, including pneumothorax in 28 patients and haematoma in 3 cases. Conclusions: Based on the obtained results, it can be stated that low-dose, CT-guided transthoracic biopsy of lung and pleural tissues is an accurate and safe procedure. Also, it is linked to a low risk of complications such as a small pneumothorax.
dc.contributor.author
Guzinski, Maciej
dc.contributor.author
Puła, Michał
dc.contributor.author
Zdanowicz, Agata
dc.contributor.author
Kacała, Arkadiusz
dc.contributor.author
Dudek, Krzysztof
dc.contributor.author
Lipiński, Artur
dc.contributor.author
Sąsiadek, Marek
dc.date.accessioned
2024-07-25T09:31:09Z
dc.date.available
2024-07-25T09:31:09Z
dc.date.issued
2023
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.additional
Bibliogr. s. e550-e551
dc.description.physical
e546-e551
dc.description.version
ostateczna wersja wydawcy
dc.description.volume
88
dc.identifier.doi
10.5114/pjr.2023.133309
dc.identifier.issn
1733-134X
dc.identifier.uri
https://ruj.uj.edu.pl/handle/item/389441
dc.language
eng
dc.language.container
eng
dc.rights
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa
dc.rights.licence
CC-BY-NC-ND
dc.rights.uri
http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl
dc.share.type
otwarte czasopismo
dc.subject.en
CT-guided biopsy
dc.subject.en
low-dose
dc.subject.en
lung biopsy
dc.subject.en
pneumothorax
dc.subject.en
haematoma
dc.subject.en
pleural biopsy
dc.subtype
Article
dc.title
Safety, feasibility, and effectiveness of a CT-guided transthoracic lung and pleural biopsy : a single-centre experience with own low-dose protocol
dc.title.journal
Polish Journal of Radiology
dc.type
JournalArticle
dspace.entity.typeen
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
9
Views per month
Views per city
Krakow
7
Wroclaw
1
Downloads
guzinski_et-al_safety_feasibility_and_effectiveness_2023.pdf
34
guzinski_safety_feasibility_and_effectiveness_2023.pdf
1