Usefulness of contrast-enhanced phase-inversion harmonic power Doppler imaging in the diagnosis of hepatic hemangiomas

2005
journal article
article
dc.abstract.enBackground: The purpose of this study was to assess the sensitivity of echo-enhanced phase-inversion power Doppler sonography (PI) in depicting the vascular enhancement of hemangiomas, thus confirming the exact diagnosis. Material/Methods: Twenty patients were examined. The presence of hemangioma was confirmed by surgical resection (n=2), two-phase (hepatic arterial and portal phases) contrast-enhanced spiral computed tomography (n=8), or sonographic follow-up, which showed no change in lesion size for at least 6 months (n=10). Prior to enhanced sonography, all patients had undergone both native B-mode and tissue harmonic imaging mode sonography, color Doppler, and power Doppler helical CT examinations. After injection of 2.5 g of Levovist intravenously, analysis of the arrival of contrast agent was performed by phase-inversion power Doppler sonography. Results: Evaluation of the 20 patients revealed 37 hemangiomas. Color and power Doppler sonography were non-specific for hemangioma in our examination. However, based on the phase-inversion power Doppler sonography findings, the 20 patients with the 37 hemangiomas were diagnosed. Typical features of hemangioma, such as peripheral globular and rim-like enhancement followed by a slow centripetal fill-in, were clearly visible. In 3 cases of small hemangiomas, computed tomography had failed to disclose the pathology, while phase-inversion sonographic images were completely suggestive of what was later confirmed at 6 months follow-up. Conclusions: Based on our results, we can recommend phase-inversion power Doppler sonography in the differential diagnosis of hemangioma by visualizing the characteristic rim-like enhancement pattern followed by a slow centripetal fill-in as an excellent diagnostic modality.pl
dc.contributor.authorJanica, Jacekpl
dc.contributor.authorPolaków, Jerzypl
dc.contributor.authorSerwatka, Wojciechpl
dc.contributor.authorUstymowicz, Andrzejpl
dc.contributor.authorŁebkowska, Urszulapl
dc.contributor.authorAlathaki, Abdulwahedpl
dc.contributor.authorWałecki, Jerzypl
dc.contributor.authorLadny, Jerzy Robertpl
dc.date.accession2021-03-26pl
dc.date.accessioned2021-03-26T11:55:47Z
dc.date.available2021-03-26T11:55:47Z
dc.date.issued2005pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. 78pl
dc.description.number3pl
dc.description.physical73-78pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume70pl
dc.identifier.articleid177562pl
dc.identifier.eissn1899-0967pl
dc.identifier.issn1733-134Xpl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/268156
dc.identifier.weblinkhttp://archiwum.inforadiologia.pl/download/index/idArt/177562.htmlpl
dc.languageengpl
dc.language.containerpolpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa*
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl*
dc.share.typeotwarte czasopismo
dc.subject.enliverpl
dc.subject.enhemangiomapl
dc.subject.encontrast mediapl
dc.subtypeArticlepl
dc.titleUsefulness of contrast-enhanced phase-inversion harmonic power Doppler imaging in the diagnosis of hepatic hemangiomaspl
dc.title.alternativePrzydatność szarokopasmowego odwróconego w fazie obrazowania harmonicznego z wykorzystaniem Dopplera mocy w diagnostyce naczyniaków wątrobypl
dc.title.journalPolish Journal of Radiologypl
dc.typeJournalArticlepl
dspace.entity.typePublication
dc.abstract.enpl
Background: The purpose of this study was to assess the sensitivity of echo-enhanced phase-inversion power Doppler sonography (PI) in depicting the vascular enhancement of hemangiomas, thus confirming the exact diagnosis. Material/Methods: Twenty patients were examined. The presence of hemangioma was confirmed by surgical resection (n=2), two-phase (hepatic arterial and portal phases) contrast-enhanced spiral computed tomography (n=8), or sonographic follow-up, which showed no change in lesion size for at least 6 months (n=10). Prior to enhanced sonography, all patients had undergone both native B-mode and tissue harmonic imaging mode sonography, color Doppler, and power Doppler helical CT examinations. After injection of 2.5 g of Levovist intravenously, analysis of the arrival of contrast agent was performed by phase-inversion power Doppler sonography. Results: Evaluation of the 20 patients revealed 37 hemangiomas. Color and power Doppler sonography were non-specific for hemangioma in our examination. However, based on the phase-inversion power Doppler sonography findings, the 20 patients with the 37 hemangiomas were diagnosed. Typical features of hemangioma, such as peripheral globular and rim-like enhancement followed by a slow centripetal fill-in, were clearly visible. In 3 cases of small hemangiomas, computed tomography had failed to disclose the pathology, while phase-inversion sonographic images were completely suggestive of what was later confirmed at 6 months follow-up. Conclusions: Based on our results, we can recommend phase-inversion power Doppler sonography in the differential diagnosis of hemangioma by visualizing the characteristic rim-like enhancement pattern followed by a slow centripetal fill-in as an excellent diagnostic modality.
dc.contributor.authorpl
Janica, Jacek
dc.contributor.authorpl
Polaków, Jerzy
dc.contributor.authorpl
Serwatka, Wojciech
dc.contributor.authorpl
Ustymowicz, Andrzej
dc.contributor.authorpl
Łebkowska, Urszula
dc.contributor.authorpl
Alathaki, Abdulwahed
dc.contributor.authorpl
Wałecki, Jerzy
dc.contributor.authorpl
Ladny, Jerzy Robert
dc.date.accessionpl
2021-03-26
dc.date.accessioned
2021-03-26T11:55:47Z
dc.date.available
2021-03-26T11:55:47Z
dc.date.issuedpl
2005
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.additionalpl
Bibliogr. s. 78
dc.description.numberpl
3
dc.description.physicalpl
73-78
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
70
dc.identifier.articleidpl
177562
dc.identifier.eissnpl
1899-0967
dc.identifier.issnpl
1733-134X
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/268156
dc.identifier.weblinkpl
http://archiwum.inforadiologia.pl/download/index/idArt/177562.html
dc.languagepl
eng
dc.language.containerpl
pol
dc.rights*
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa
dc.rights.licence
CC-BY-NC-ND
dc.rights.uri*
http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl
dc.share.type
otwarte czasopismo
dc.subject.enpl
liver
dc.subject.enpl
hemangioma
dc.subject.enpl
contrast media
dc.subtypepl
Article
dc.titlepl
Usefulness of contrast-enhanced phase-inversion harmonic power Doppler imaging in the diagnosis of hepatic hemangiomas
dc.title.alternativepl
Przydatność szarokopasmowego odwróconego w fazie obrazowania harmonicznego z wykorzystaniem Dopplera mocy w diagnostyce naczyniaków wątroby
dc.title.journalpl
Polish Journal of Radiology
dc.typepl
JournalArticle
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
30
Views per month
Views per city
Dublin
8
Chandler
2
Lomé
2
Wroclaw
2
Brussels
1
Bühl
1
Helsinki
1
Sofia
1
Downloads
janica_polakow_serwatka_ustymowicz_lebkowska_alathaki_walecki_ladny_usefulness_of_contrast-enhanced_phase-inversion_harmonic_power_2005.pdf
15