dc.abstract.enPurpose: Early depiction of bony erosions in sacroiliac (SI) joints increases the diagnostic accuracy of spondyloarthritis. The new 3D magnetic resonance imaging (MRI) sequence THRIVE (T1-weighted high-resolution isotropic volume examination) can depict cartilage erosions in sacroiliac joints. The aim of the study was to compare the diagnostic capacity of the new MRI sequence 3D THRIVE (T1-weighted high-resolution isotropic volume examination) with the routinely used T1 TSE pulse sequence in the depiction of structural erosions in sacroiliac joints by using MRI sequence zero echo time (zero ET) as a reference standard. Material and methods: Seventy five adult patients were included in this study. They underwent MRI sacroiliac joints examination using routine T1 TSE and STIR pulse sequences with the addition of the new 3D THRIVE and zero echo time (zero ET) sequences. Images of T1 TSE, 3D THRIVE, and zero ET sequences were evaluated by 2 radiologists separately for the detection of sacroiliac joints erosions, then a comparison between T1 TSE and 3D THRIVE sequences was done using a CT-like image MRI sequence zero ET as a reference standard. Sensitivity, specificity, and accuracy for each sequence were calculated by the 2 readers. Results: Sensitivity, specificity, and accuracy of 3D THRIVE were higher than those of T1 TSE for reader 1 (sensitivity: 94.5% vs. 86.2%; specificity: 93.4% vs. 85.1%; and accuracy 95.2% vs. 88.5%) and for reader 2 (sensitivity: 93.3% vs. 79.9%; specificity: 94.7% vs. 86.2%; and accuracy 95.8% vs. 82.1%). Conclusions: Using CT-like image MRI sequence zero ET as the reference standard, 3D THRIVE pulse sequencing of the sacroiliac joints has much better diagnostic value in the depiction of bony erosions in patients suspected having spondyloarthritis as compared to the routinely used T1 TSE sequence.
dc.contributor.authorTawfik, Ahmed Ibrahim
dc.contributor.authorHarraz, Mohamed M.
dc.contributor.authorBaky, Khaled Abdel
dc.contributor.authorMahmoud, Walaa
dc.date.accessioned2024-07-24T09:25:27Z
dc.date.available2024-07-24T09:25:27Z
dc.date.issued2023
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. e511
dc.description.physicale506-e511
dc.description.versionostateczna wersja wydawcy
dc.description.volume88
dc.identifier.doi10.5114/pjr.2023.132877
dc.identifier.issn1733-134X
dc.identifier.urihttps://ruj.uj.edu.pl/handle/item/389327
dc.languageeng
dc.language.containereng
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl
dc.share.typeotwarte czasopismo
dc.subject.ensacroiliac joints
dc.subject.enT1-weighted high-resolution isotropic volume examination
dc.subject.enT1 turbo spin echo
dc.subject.enmagnetic resonance imaging
dc.subtypeArticle
dc.titleAdded value of 3D THRIVE (T1-weighted high-resolution isotropic volume examination) MRI pulse sequence in the detection of bony erosions of sacroiliac joints in patients of spondyloarthritis
dc.title.journalPolish Journal of Radiology
dc.typeJournalArticle
dspace.entity.typePublicationen
dc.abstract.en
Purpose: Early depiction of bony erosions in sacroiliac (SI) joints increases the diagnostic accuracy of spondyloarthritis. The new 3D magnetic resonance imaging (MRI) sequence THRIVE (T1-weighted high-resolution isotropic volume examination) can depict cartilage erosions in sacroiliac joints. The aim of the study was to compare the diagnostic capacity of the new MRI sequence 3D THRIVE (T1-weighted high-resolution isotropic volume examination) with the routinely used T1 TSE pulse sequence in the depiction of structural erosions in sacroiliac joints by using MRI sequence zero echo time (zero ET) as a reference standard. Material and methods: Seventy five adult patients were included in this study. They underwent MRI sacroiliac joints examination using routine T1 TSE and STIR pulse sequences with the addition of the new 3D THRIVE and zero echo time (zero ET) sequences. Images of T1 TSE, 3D THRIVE, and zero ET sequences were evaluated by 2 radiologists separately for the detection of sacroiliac joints erosions, then a comparison between T1 TSE and 3D THRIVE sequences was done using a CT-like image MRI sequence zero ET as a reference standard. Sensitivity, specificity, and accuracy for each sequence were calculated by the 2 readers. Results: Sensitivity, specificity, and accuracy of 3D THRIVE were higher than those of T1 TSE for reader 1 (sensitivity: 94.5% vs. 86.2%; specificity: 93.4% vs. 85.1%; and accuracy 95.2% vs. 88.5%) and for reader 2 (sensitivity: 93.3% vs. 79.9%; specificity: 94.7% vs. 86.2%; and accuracy 95.8% vs. 82.1%). Conclusions: Using CT-like image MRI sequence zero ET as the reference standard, 3D THRIVE pulse sequencing of the sacroiliac joints has much better diagnostic value in the depiction of bony erosions in patients suspected having spondyloarthritis as compared to the routinely used T1 TSE sequence.
dc.contributor.author
Tawfik, Ahmed Ibrahim
dc.contributor.author
Harraz, Mohamed M.
dc.contributor.author
Baky, Khaled Abdel
dc.contributor.author
Mahmoud, Walaa
dc.date.accessioned
2024-07-24T09:25:27Z
dc.date.available
2024-07-24T09:25:27Z
dc.date.issued
2023
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.additional
Bibliogr. s. e511
dc.description.physical
e506-e511
dc.description.version
ostateczna wersja wydawcy
dc.description.volume
88
dc.identifier.doi
10.5114/pjr.2023.132877
dc.identifier.issn
1733-134X
dc.identifier.uri
https://ruj.uj.edu.pl/handle/item/389327
dc.language
eng
dc.language.container
eng
dc.rights
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa
dc.rights.licence
CC-BY-NC-ND
dc.rights.uri
http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl
dc.share.type
otwarte czasopismo
dc.subject.en
sacroiliac joints
dc.subject.en
T1-weighted high-resolution isotropic volume examination
dc.subject.en
T1 turbo spin echo
dc.subject.en
magnetic resonance imaging
dc.subtype
Article
dc.title
Added value of 3D THRIVE (T1-weighted high-resolution isotropic volume examination) MRI pulse sequence in the detection of bony erosions of sacroiliac joints in patients of spondyloarthritis
dc.title.journal
Polish Journal of Radiology
dc.type
JournalArticle
dspace.entity.typeen
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
6
Views per month
Views per city
Krakow
5
Downloads
tawfik_et-al_added_value_of_3d_thrive_2023.pdf
4