Performance of different cone-beam computed tomography scan modes with and without metal artifact reduction in detection of recurrent dental caries under various restorative materials

2024
journal article
article
dc.abstract.enPurpose: We aimed to compare the diagnostic performance of different cone-beam computed tomography (CBCT) scan modes with and without the application of a metal artifact reduction (MAR) option under 5 different restorative materials. Material and methods: Our research was an in vitro study with 150 caries-free premolars and molars. The teeth were randomly divided into experimental (with artificially induced caries, n = 75) and control (without caries, n = 75) groups and were prepared based on 5 types of restorative materials, including conventional composites (Filtek Z250, Gradia), flow composite, glass ionomer, and amalgam. The teeth were examined under 2 CBCT scan modes (high-resolution [HIRes] and standard) with and without MAR application. Finally, the diagnostic accuracy index values (area under the receiver operating characteristic curve [AUC], sensitivity, and specificity) were calculated. Results: The AUC of standard scan mode with the MAR option was significantly lower than that of HIRes with MAR (p = 0.018) and without MAR option (p = 0.011) in detecting recurrent caries. Also, without MAR option, the diagnostic accuracy (AUC) of the standard mode was significantly lower than that of the HIRes (p = 0.020). Similar findings were observed for sensitivity and specificity. Moreover, diagnostic performance of standard and HIRes scan modes with and without MAR in the amalgam group was lower than that in other restorative material groups. Conclusions: Diagnostic performance of HIRes CBCT mode was higher than that of standard mode for recurrent caries and remained unaffected by MAR application. However, the accuracy in detecting recurrent caries was lower in the amalgam group compared with other restorative material groups.
dc.contributor.authorAbesi, Farida
dc.contributor.authorTalachi, Fatemehzahra
dc.contributor.authorEzoji, Fariba
dc.date.accessioned2025-07-31T07:28:13Z
dc.date.available2025-07-31T07:28:13Z
dc.date.createdat2025-07-31T07:28:13Zen
dc.date.issued2024
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. e290-e291
dc.description.physicale281-e291
dc.description.versionostateczna wersja wydawcy
dc.description.volume89
dc.identifier.doi10.5114/pjr/188257
dc.identifier.issn1733-134X
dc.identifier.projectDRC AI
dc.identifier.urihttps://ruj.uj.edu.pl/handle/item/558581
dc.languageeng
dc.language.containereng
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl
dc.share.typeotwarte czasopismo
dc.subject.encone-beam computed tomography
dc.subject.enmetal artifact reduction
dc.subject.endental caries
dc.subject.enrestorative materials
dc.subject.enaccuracy
dc.subtypeArticle
dc.titlePerformance of different cone-beam computed tomography scan modes with and without metal artifact reduction in detection of recurrent dental caries under various restorative materials
dc.title.journalPolish Journal of Radiology
dc.typeJournalArticle
dspace.entity.typePublicationen
dc.abstract.en
Purpose: We aimed to compare the diagnostic performance of different cone-beam computed tomography (CBCT) scan modes with and without the application of a metal artifact reduction (MAR) option under 5 different restorative materials. Material and methods: Our research was an in vitro study with 150 caries-free premolars and molars. The teeth were randomly divided into experimental (with artificially induced caries, n = 75) and control (without caries, n = 75) groups and were prepared based on 5 types of restorative materials, including conventional composites (Filtek Z250, Gradia), flow composite, glass ionomer, and amalgam. The teeth were examined under 2 CBCT scan modes (high-resolution [HIRes] and standard) with and without MAR application. Finally, the diagnostic accuracy index values (area under the receiver operating characteristic curve [AUC], sensitivity, and specificity) were calculated. Results: The AUC of standard scan mode with the MAR option was significantly lower than that of HIRes with MAR (p = 0.018) and without MAR option (p = 0.011) in detecting recurrent caries. Also, without MAR option, the diagnostic accuracy (AUC) of the standard mode was significantly lower than that of the HIRes (p = 0.020). Similar findings were observed for sensitivity and specificity. Moreover, diagnostic performance of standard and HIRes scan modes with and without MAR in the amalgam group was lower than that in other restorative material groups. Conclusions: Diagnostic performance of HIRes CBCT mode was higher than that of standard mode for recurrent caries and remained unaffected by MAR application. However, the accuracy in detecting recurrent caries was lower in the amalgam group compared with other restorative material groups.
dc.contributor.author
Abesi, Farida
dc.contributor.author
Talachi, Fatemehzahra
dc.contributor.author
Ezoji, Fariba
dc.date.accessioned
2025-07-31T07:28:13Z
dc.date.available
2025-07-31T07:28:13Z
dc.date.createdaten
2025-07-31T07:28:13Z
dc.date.issued
2024
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.additional
Bibliogr. s. e290-e291
dc.description.physical
e281-e291
dc.description.version
ostateczna wersja wydawcy
dc.description.volume
89
dc.identifier.doi
10.5114/pjr/188257
dc.identifier.issn
1733-134X
dc.identifier.project
DRC AI
dc.identifier.uri
https://ruj.uj.edu.pl/handle/item/558581
dc.language
eng
dc.language.container
eng
dc.rights
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa
dc.rights.licence
CC-BY-NC-ND
dc.rights.uri
http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl
dc.share.type
otwarte czasopismo
dc.subject.en
cone-beam computed tomography
dc.subject.en
metal artifact reduction
dc.subject.en
dental caries
dc.subject.en
restorative materials
dc.subject.en
accuracy
dc.subtype
Article
dc.title
Performance of different cone-beam computed tomography scan modes with and without metal artifact reduction in detection of recurrent dental caries under various restorative materials
dc.title.journal
Polish Journal of Radiology
dc.type
JournalArticle
dspace.entity.typeen
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
10
Views per month
Views per city
Krakow
8
Poznan
1
Singapore
1
Downloads
abesi_talachi_ezoji_performance_of_different_cone-beam_computed_tomography_scan_2024.pdf
14