Performance of different cone-beam computed tomography scan modes with and without metal artifact reduction in detection of recurrent dental caries under various restorative materials
cone-beam computed tomography
metal artifact reduction
dental caries
restorative materials
accuracy
Bibliogr. s. e290-e291
Purpose: We aimed to compare the diagnostic performance of different cone-beam computed tomography (CBCT) scan modes with and without the application of a metal artifact reduction (MAR) option under 5 different restorative materials. Material and methods: Our research was an in vitro study with 150 caries-free premolars and molars. The teeth were randomly divided into experimental (with artificially induced caries, n = 75) and control (without caries, n = 75) groups and were prepared based on 5 types of restorative materials, including conventional composites (Filtek Z250, Gradia), flow composite, glass ionomer, and amalgam. The teeth were examined under 2 CBCT scan modes (high-resolution [HIRes] and standard) with and without MAR application. Finally, the diagnostic accuracy index values (area under the receiver operating characteristic curve [AUC], sensitivity, and specificity) were calculated. Results: The AUC of standard scan mode with the MAR option was significantly lower than that of HIRes with MAR (p = 0.018) and without MAR option (p = 0.011) in detecting recurrent caries. Also, without MAR option, the diagnostic accuracy (AUC) of the standard mode was significantly lower than that of the HIRes (p = 0.020). Similar findings were observed for sensitivity and specificity. Moreover, diagnostic performance of standard and HIRes scan modes with and without MAR in the amalgam group was lower than that in other restorative material groups. Conclusions: Diagnostic performance of HIRes CBCT mode was higher than that of standard mode for recurrent caries and remained unaffected by MAR application. However, the accuracy in detecting recurrent caries was lower in the amalgam group compared with other restorative material groups.
| dc.abstract.en | Purpose: We aimed to compare the diagnostic performance of different cone-beam computed tomography (CBCT) scan modes with and without the application of a metal artifact reduction (MAR) option under 5 different restorative materials. Material and methods: Our research was an in vitro study with 150 caries-free premolars and molars. The teeth were randomly divided into experimental (with artificially induced caries, n = 75) and control (without caries, n = 75) groups and were prepared based on 5 types of restorative materials, including conventional composites (Filtek Z250, Gradia), flow composite, glass ionomer, and amalgam. The teeth were examined under 2 CBCT scan modes (high-resolution [HIRes] and standard) with and without MAR application. Finally, the diagnostic accuracy index values (area under the receiver operating characteristic curve [AUC], sensitivity, and specificity) were calculated. Results: The AUC of standard scan mode with the MAR option was significantly lower than that of HIRes with MAR (p = 0.018) and without MAR option (p = 0.011) in detecting recurrent caries. Also, without MAR option, the diagnostic accuracy (AUC) of the standard mode was significantly lower than that of the HIRes (p = 0.020). Similar findings were observed for sensitivity and specificity. Moreover, diagnostic performance of standard and HIRes scan modes with and without MAR in the amalgam group was lower than that in other restorative material groups. Conclusions: Diagnostic performance of HIRes CBCT mode was higher than that of standard mode for recurrent caries and remained unaffected by MAR application. However, the accuracy in detecting recurrent caries was lower in the amalgam group compared with other restorative material groups. | |
| dc.contributor.author | Abesi, Farida | |
| dc.contributor.author | Talachi, Fatemehzahra | |
| dc.contributor.author | Ezoji, Fariba | |
| dc.date.accessioned | 2025-07-31T07:28:13Z | |
| dc.date.available | 2025-07-31T07:28:13Z | |
| dc.date.createdat | 2025-07-31T07:28:13Z | en |
| dc.date.issued | 2024 | |
| dc.date.openaccess | 0 | |
| dc.description.accesstime | w momencie opublikowania | |
| dc.description.additional | Bibliogr. s. e290-e291 | |
| dc.description.physical | e281-e291 | |
| dc.description.version | ostateczna wersja wydawcy | |
| dc.description.volume | 89 | |
| dc.identifier.doi | 10.5114/pjr/188257 | |
| dc.identifier.issn | 1733-134X | |
| dc.identifier.project | DRC AI | |
| dc.identifier.uri | https://ruj.uj.edu.pl/handle/item/558581 | |
| dc.language | eng | |
| dc.language.container | eng | |
| dc.rights | Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa | |
| dc.rights.licence | CC-BY-NC-ND | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl | |
| dc.share.type | otwarte czasopismo | |
| dc.subject.en | cone-beam computed tomography | |
| dc.subject.en | metal artifact reduction | |
| dc.subject.en | dental caries | |
| dc.subject.en | restorative materials | |
| dc.subject.en | accuracy | |
| dc.subtype | Article | |
| dc.title | Performance of different cone-beam computed tomography scan modes with and without metal artifact reduction in detection of recurrent dental caries under various restorative materials | |
| dc.title.journal | Polish Journal of Radiology | |
| dc.type | JournalArticle | |
| dspace.entity.type | Publication | en |
* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.
Views
10
Views per month
Views per city
Downloads
Open Access