Jagiellonian University Repository

Different sensitivities of two optical magnetometers realized in the same experimental arrangement

pcg.skipToMenu

Different sensitivities of two optical magnetometers realized in the same experimental arrangement

Show full item record

dc.contributor.author Put, Piotr [USOS161170] pl
dc.contributor.author Popiołek, Kacper [USOS230817] pl
dc.contributor.author Pustelny, Szymon [SAP11019465] pl
dc.date.accessioned 2019-04-10T12:35:11Z
dc.date.available 2019-04-10T12:35:11Z
dc.date.issued 2019 pl
dc.identifier.uri https://ruj.uj.edu.pl/xmlui/handle/item/72718
dc.language eng pl
dc.rights Udzielam licencji. Uznanie autorstwa 4.0 Międzynarodowa *
dc.rights.uri http://creativecommons.org/licenses/by/4.0/pl/legalcode *
dc.title Different sensitivities of two optical magnetometers realized in the same experimental arrangement pl
dc.type JournalArticle pl
dc.abstract.en In this article, operation of optical magnetometers detecting static (DC) and oscillating (AC) magnetic fields is studied and comparison of the devices is performed. To facilitate the comparison, the analysis is carried out in the same experimental setup, exploiting nonlinear magneto-optical rotation. In such a system, a control over static-field magnitude or oscillating-field frequency provides detection of strength of the DC or AC fields. Polarization rotation is investigated for various light intensities and AC-field amplitudes, which allows to determine optimum sensitivity to both fields. With the results, we demonstrate that under optimal conditions the AC magnetometer is about ten times more sensitive than its DC counterpart, which originates from different response of the atoms to the fields. Bandwidth of the magnetometers is also analyzed, revealing its different dependence on the light power. Particularly, we demonstrate that bandwidth of the AC magnetometer can be significantly increased without strong deterioration of the magnetometer sensitivity. This behavior, combined with the ability to tune the resonance frequency of the AC magnetometer, provide means for ultra-sensitive measurements of the AC field in a broad but spectrally-limited range, where detrimental role of static-field instability is significantly reduced. pl
dc.description.volume 9 pl
dc.identifier.doi 10.1038/s41598-019-39282-3 pl
dc.identifier.eissn 2045-2322 pl
dc.title.journal Scientific Reports pl
dc.language.container eng pl
dc.affiliation Wydział Fizyki, Astronomii i Informatyki Stosowanej : Instytut Fizyki im. Mariana Smoluchowskiego pl
dc.subtype Article pl
dc.identifier.articleid 2537 pl
dc.rights.original CC-BY; otwarte czasopismo; ostateczna wersja wydawcy; w momencie opublikowania; 0 pl
dc.identifier.project ROD UJ / OP pl
.pointsMNiSW [2019 A]: 140


Files in this item

This item appears in the following Collection(s)

Udzielam licencji. Uznanie autorstwa 4.0 Międzynarodowa Except where otherwise noted, this item's license is described as Udzielam licencji. Uznanie autorstwa 4.0 Międzynarodowa