Jagiellonian University Repository

Abdominal aorta aneurysm : case report of high radiation dose during stent-graft implantation

Abdominal aorta aneurysm : case report of high ...

Show full item record

dc.contributor.author Majewska, Natalia pl
dc.contributor.author Juszkat, Robert pl
dc.contributor.author Błaszak, Magdalena pl
dc.contributor.author Frankiewicz, Maciej pl
dc.contributor.author Makalowski, Marcin pl
dc.contributor.author Stanisić, Michał pl
dc.contributor.author Wachal, Krzysztof pl
dc.contributor.author Majewski, Wacław pl
dc.date.accessioned 2018-09-18T09:14:56Z
dc.date.available 2018-09-18T09:14:56Z
dc.date.issued 2011 pl
dc.identifier.issn 1733-134X pl
dc.identifier.uri https://ruj.uj.edu.pl/xmlui/handle/item/57041
dc.language eng pl
dc.rights Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/4.0/pl/legalcode *
dc.title Abdominal aorta aneurysm : case report of high radiation dose during stent-graft implantation pl
dc.type JournalArticle pl
dc.description.physical 60-62 pl
dc.description.additional Bibliogr. s. 62 pl
dc.identifier.weblink http://archiwum.polradiol.com/abstract/index/idArt/882147 pl
dc.abstract.en This study is a case report regarding a possible problem of high radiation dose during stent-graft implantation. Before deciding on how to treat an aneurysm (stent grafting or traditional surgery), possible complications such as difficult anatomical conditions and diseases of the aorta and iliac arteries should be considered to avoid potentially high doses of radiation. In case of this patient, it was very difficult to introduce a guidewire through the contralateral limb into the body of the graft due to tortuosity and kinking of iliac arteries. Because of the long duration of the procedure (68 min), the patient was exposed to a very high radiation dose (4.37 Gy) and DAP (1760.3 Gy cm²). pl
dc.subject.en abdominal stentgraft pl
dc.subject.en high dose pl
dc.subject.en X-ray pl
dc.subject.en radiation pl
dc.description.volume 76 pl
dc.description.number 4 pl
dc.identifier.eissn 1899-0967 pl
dc.title.journal Polish Journal of Radiology pl
dc.language.container eng pl
dc.date.accession 2018-09-18 pl
dc.subtype Article pl
dc.identifier.articleid 882147 pl
dc.rights.original CC-BY-NC-ND; otwarte czasopismo; ostateczna wersja wydawcy; w momencie opublikowania; 0 pl
dc.identifier.project ROD UJ / OP pl


Files in this item

This item appears in the following Collection(s)

Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa Except where otherwise noted, this item's license is described as Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa