Abdominal aorta aneurysm : case report of high radiation dose during stent-graft implantation

2011
journal article
article
dc.abstract.enThis study is a case report regarding a possible problem of high radiation dose during stent-graft implantation. Before deciding on how to treat an aneurysm (stent grafting or traditional surgery), possible complications such as difficult anatomical conditions and diseases of the aorta and iliac arteries should be considered to avoid potentially high doses of radiation. In case of this patient, it was very difficult to introduce a guidewire through the contralateral limb into the body of the graft due to tortuosity and kinking of iliac arteries. Because of the long duration of the procedure (68 min), the patient was exposed to a very high radiation dose (4.37 Gy) and DAP (1760.3 Gy cm²).pl
dc.contributor.authorMajewska, Nataliapl
dc.contributor.authorJuszkat, Robertpl
dc.contributor.authorBłaszak, Magdalenapl
dc.contributor.authorFrankiewicz, Maciejpl
dc.contributor.authorMakalowski, Marcinpl
dc.contributor.authorStanisić, Michałpl
dc.contributor.authorWachal, Krzysztofpl
dc.contributor.authorMajewski, Wacławpl
dc.date.accession2018-09-18pl
dc.date.accessioned2018-09-18T09:14:56Z
dc.date.available2018-09-18T09:14:56Z
dc.date.issued2011pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. 62pl
dc.description.number4pl
dc.description.physical60-62pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume76pl
dc.identifier.articleid882147pl
dc.identifier.eissn1899-0967pl
dc.identifier.issn1733-134Xpl
dc.identifier.projectROD UJ / OPpl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/57041
dc.identifier.weblinkhttp://archiwum.polradiol.com/abstract/index/idArt/882147pl
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa*
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl*
dc.share.typeotwarte czasopismo
dc.subject.enabdominal stentgraftpl
dc.subject.enhigh dosepl
dc.subject.enX-raypl
dc.subject.enradiationpl
dc.subtypeArticlepl
dc.titleAbdominal aorta aneurysm : case report of high radiation dose during stent-graft implantationpl
dc.title.journalPolish Journal of Radiologypl
dc.typeJournalArticlepl
dspace.entity.typePublication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
0
Views per month