Jagiellonian University Repository

CT imaging of facial trauma : the role of different types of reconstruction : part II : soft tissues

CT imaging of facial trauma : the role of different ...

Show full item record

dc.contributor.author Myga-Porosiło, Jolanta pl
dc.contributor.author Skrzelewski, Stanisław pl
dc.contributor.author Sraga, Wojciech pl
dc.contributor.author Borowiak, Hanna pl
dc.contributor.author Jackowska, Zuzanna pl
dc.contributor.author Kluczewska, Ewa pl
dc.date.accessioned 2018-08-27T11:49:15Z
dc.date.available 2018-08-27T11:49:15Z
dc.date.issued 2011 pl
dc.identifier.issn 1733-134X pl
dc.identifier.uri https://ruj.uj.edu.pl/xmlui/handle/item/56468
dc.language eng pl
dc.rights Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/4.0/pl/legalcode *
dc.title CT imaging of facial trauma : the role of different types of reconstruction : part II : soft tissues pl
dc.title.alternative Badanie TK w urazach części twarzowej czaszki : znaczenie różnych typów rekonstrukcji : część II : tkanki miękkie pl
dc.type JournalArticle pl
dc.description.physical 52-58 pl
dc.description.additional Bibliogr. s. 57-58 pl
dc.identifier.weblink http://archiwum.polradiol.com/abstract/index/idArt/881409 pl
dc.abstract.en Background: Injury to facial soft tissues as a complication of skeleton fractures is an important problem among patients with facial trauma. The aim of this work was to assess the value of multiplanar and three-dimensional (3D) reconstruction computed tomography (CT) images obtained by using multi-detector row technology in spiral data acquisition in patients with facial injuries of soft tissue. Material/Methods: Sixty-seven patients diagnosed with injury to the facial skeleton underwent a CT scan with the use of GE Hispeed Qx/i scanner. For each patient: a two-dimensional (2D) multiplanar reconstruction (MPR), maximum intensity projection (MIP), and 3D volume rendering (VR) were conducted. Post-injury lesions of soft tissues were assessed. During the assessment of the post-injury lesions of soft tissues, the following features were evaluated: Extraocular muscle and fat tissue herniation through fractures in the medial and inferior orbital walls. Fluid in the sinuses and in the nasal cavity. Subcutaneous tissue emphysema. Results: For subcutaneous emphysema and sinus fluid imaging, both the axial and the 2D image reconstruction proved comparably effective. However, 2D reconstructions were superior to transverse plane images with regard to herniations into fractures of the inferior orbital wall. 3D reconstruction has no importance in diagnosing soft tissue injuries. Conclusions: Multiplanar CT reconstructions increase the effectiveness of imaging of orbital tissue herniations, especially in case of fractures in the inferior orbital wall. In suspected soft tissue herniations, as well as prior to surgical treatment, spiral CT with 2D multiplanar reconstructions should be the method of choice. pl
dc.subject.en facial injuries pl
dc.subject.en soft tissue injuries pl
dc.subject.en computed tomography pl
dc.subject.en CT pl
dc.description.volume 76 pl
dc.description.number 1 pl
dc.identifier.eissn 1899-0967 pl
dc.title.journal Polish Journal of Radiology pl
dc.language.container eng pl
dc.date.accession 2018-08-27 pl
dc.subtype Article pl
dc.identifier.articleid 881409 pl
dc.rights.original CC-BY-NC-ND; otwarte czasopismo; ostateczna wersja wydawcy; w momencie opublikowania; 0 pl
dc.identifier.project ROD UJ / OP pl


Files in this item

This item appears in the following Collection(s)

Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa Except where otherwise noted, this item's license is described as Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa