Jagiellonian University Repository

Novel detector systems for the Positron Emission Tomography

pcg.skipToMenu

Novel detector systems for the Positron Emission Tomography

Show full item record

dc.contributor.author Moskal, Paweł [SAP11015350] pl
dc.contributor.author Salabura, Piotr [SAP11011883] pl
dc.contributor.author Silarski, Michał [SAP13036814] pl
dc.contributor.author Smyrski, Jerzy [SAP11011139] pl
dc.contributor.author Zdebik, Jarosław [USOS2045] pl
dc.contributor.author Zieliński, Marcin [SAP13036834] pl
dc.date.accessioned 2016-11-29T08:58:22Z
dc.date.available 2016-11-29T08:58:22Z
dc.date.issued 2011 pl
dc.identifier.issn 1895-9091 pl
dc.identifier.uri http://ruj.uj.edu.pl/xmlui/handle/item/33021
dc.language eng pl
dc.rights Dodaję tylko opis bibliograficzny *
dc.rights.uri *
dc.title Novel detector systems for the Positron Emission Tomography pl
dc.type JournalArticle pl
dc.description.physical 73-78 pl
dc.identifier.weblink http://koza.if.uj.edu.pl/files/2fc1e3c5fd2bc6af6c8c8ad6ec5d57a1/MZ20120330_bams14_73.pdf pl
dc.identifier.weblink https://www.researchgate.net/publication/236887259 pl
dc.abstract.en In this contribution we describe a novel solution for the construction of Positron Emission Tomograph. We present the device allowing for determination of the impact position as well as time and depth of interaction of the annihilation gamma quanta. The device is comprised of scintillation chamber consisting of organic scintillators surrounding the body of the patient. We discuss two possible solutions: (i) the tomograph built out of scintillator strips, and (ii) the tomograph built out of the scintillator plates. The application of the fast scintillators will enable to take advantage of the difference between time of the registration of the annihilation quanta. The invented method will permit to use a thick layers of detector material with the possibility of measuring the depth of the gamma quantum interaction (DOI) and the determination of their time of fl ight (TOF), and will allow for increasing the size of the diagnostic chamber without a signifi cant increase of costs. The method is a subject of two patent applications [1, 2] which are based on the techniques used in the particle physics experiments [3, 4]. pl
dc.description.volume 7 pl
dc.description.number 2 pl
dc.identifier.eissn 1896-530X pl
dc.title.journal Bio-Algorithms and Med-Systems pl
dc.language.container eng pl
dc.date.accession 2016-11-29 pl
dc.affiliation Wydział Fizyki, Astronomii i Informatyki Stosowanej : Instytut Fizyki im. Mariana Smoluchowskiego pl
dc.subtype Article pl
.pointsMNiSW [2011 B]: 5


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)