Jagiellonian University Repository

Determination of silver traces in pure metallic copper and zinc by a catalytic photometric method

pcg.skipToMenu

Determination of silver traces in pure metallic copper and zinc by a catalytic photometric method

Show full item record

dc.contributor.author Sulka, Grzegorz [SAP11115744] pl
dc.contributor.author Jaskuła, Marian [SAP11005670] pl
dc.date.accessioned 2020-12-07T14:24:03Z
dc.date.available 2020-12-07T14:24:03Z
dc.date.issued 2007 pl
dc.identifier.issn 0011-1643 pl
dc.identifier.uri https://ruj.uj.edu.pl/xmlui/handle/item/258340
dc.language eng pl
dc.rights Udzielam licencji. Uznanie autorstwa 4.0 Międzynarodowa *
dc.rights.uri http://creativecommons.org/licenses/by/4.0/pl/legalcode *
dc.title Determination of silver traces in pure metallic copper and zinc by a catalytic photometric method pl
dc.type JournalArticle pl
dc.description.physical 147-150 pl
dc.description.additional Bibliogr. s. 150. pl
dc.identifier.weblink https://hrcak.srce.hr/12837 pl
dc.abstract.en Determination of silver traces in the presence of copper, zinc and sulphate ions by a catalytic method was studied. The highly sensitive method of silver determination is based on the catalytic effect of silver ions on the oxidation of salicylic acid by persulphate in the presence of 2,2'-dipyridyl as an activator. The reaction was followed spectrophotometrically by measuring the rate of change in absorbance with time at 420 nm after 10 min of reagents mixing. The sensitivity, precision and accuracy of the determination of silver traces were investigated in solutions containing excesses of interfering ions. The studied range of interfering ions concentrations was 8 × 10–6 to 2.4 × 10–2 mol dm–3 and corresponds to an amount ratio of interfering to silver ions from 50 to 150 000. The performed analyses showed that the accuracy and precision of silver trace determination by the proposed method is high even in the presence of a huge amount excess of interfering ions. The method was used for quantitative determination of silver contents in a copper foil and in a zinc rod. The obtained results were compared with the analyses performed by FAAS. pl
dc.subject.en silver traces pl
dc.subject.en kinetics based analytical methods pl
dc.subject.en copper ion interference pl
dc.subject.en zinc ion interference pl
dc.subject.en sulphate ion interference pl
dc.description.volume 80 pl
dc.description.number 1 pl
dc.identifier.eissn 1334-417X pl
dc.title.journal Croatica Chemica Acta pl
dc.language.container eng pl
dc.date.accession 2020-12-07 pl
dc.affiliation Wydział Chemii : Zakład Chemii Fizycznej i Elektrochemii pl
dc.subtype Article pl
dc.rights.original CC-BY; otwarte czasopismo; ostateczna wersja wydawcy; w momencie opublikowania; 0 pl
dc.identifier.project ROD UJ / OP pl


Files in this item

This item appears in the following Collection(s)

Udzielam licencji. Uznanie autorstwa 4.0 Międzynarodowa Except where otherwise noted, this item's license is described as Udzielam licencji. Uznanie autorstwa 4.0 Międzynarodowa