Reduction in radioactive internal contamination by 99mTc among medical personnel in nuclear medicine facilities with the use of respiratory tract protection measures

2022
journal article
article
cris.lastimport.wos2024-04-10T01:34:20Z
dc.abstract.enThe main objective of the present publication was to assess the reduction of internal radioactive contamination with $^{99m}$Tc among medical personnel of nuclear medicine facilities using generally available respiratory tract protection systems. During the current research project, four respiratory tract protection systems were tested by estimation of $^{99m}$Tc activity levels in blood samples collected from medical personnel. Medical staf were equipped with a disposable surgical mask, a half mask with gas absorbers, a half mask with aerosol absorbers and a half mask with gas absorbers with added Petryanov flter. The presented results indicate that wearing only a disposable surgical mask may signifcantly reduce radioactive internal contamination among medical personnel and improve their safety in the workplace. The best results of reduced $^{99m}$Tc concentration in the blood were achieved by the use of a half mask with gas absorbers with added Pertryanov flters and a half mask with aerosol absorbers, where the reduction factors were estimated at 90% and 80%, respectively. Respiratory tract protection systems should become standard equipment for medical personnel performing ventilation–perfusion SPECT lung scans.pl
dc.affiliationWydział Nauk o Zdrowiupl
dc.affiliationWydział Lekarski : Instytut Kardiologiipl
dc.affiliationWydział Fizyki, Astronomii i Informatyki Stosowanej : Instytut Fizyki im. Mariana Smoluchowskiegopl
dc.cm.date2022-12-18T23:17:58Z
dc.cm.id110610pl
dc.cm.idOmegaUJCM05bb87bd3c914fa6a907dc3893e88100pl
dc.contributor.authorBrudecki, Kamilpl
dc.contributor.authorBorkowska, Eliza - 216315 pl
dc.contributor.authorGorzkiewicz, Krzysztofpl
dc.contributor.authorKostkiewicz, Magdalena - 130307 pl
dc.contributor.authorMisiak, Ryszardpl
dc.contributor.authorMróz, Tomasz - 395056 pl
dc.contributor.authorNalichowska, Ewapl
dc.date.accession2022-12-16pl
dc.date.accessioned2022-12-18T23:17:58Z
dc.date.available2022-12-18T23:17:58Z
dc.date.issued2022pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalOnline First 2022-11-24pl
dc.description.number1pl
dc.description.physical5061-5065pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume331pl
dc.identifier.doi10.1007/s10967-022-08639-wpl
dc.identifier.eissn1588-2780pl
dc.identifier.issn0236-5731pl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/304878
dc.identifier.weblinkhttps://link.springer.com/article/10.1007/s10967-022-08639-wpl
dc.languageengpl
dc.language.containerengpl
dc.pbn.affiliationDziedzina nauk medycznych i nauk o zdrowiu : nauki medyczne
dc.rightsUdzielam licencji. Uznanie autorstwa 4.0 Międzynarodowa*
dc.rights.licenceCC-BY
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/legalcode.pl*
dc.share.typeOtwarte czasopismo
dc.subject.en$^{99m}$Tcpl
dc.subject.eninternal contaminationpl
dc.subject.enmedical personnelpl
dc.subject.enbloodpl
dc.subject.enlungpl
dc.subject.enperfusionpl
dc.subject.enventilationpl
dc.subject.enscintigraphypl
dc.subtypeArticlepl
dc.titleReduction in radioactive internal contamination by 99mTc among medical personnel in nuclear medicine facilities with the use of respiratory tract protection measurespl
dc.title.journalJournal of Radioanalytical and Nuclear Chemistrypl
dc.typeJournalArticlepl
dspace.entity.typePublication
cris.lastimport.wos
2024-04-10T01:34:20Z
dc.abstract.enpl
The main objective of the present publication was to assess the reduction of internal radioactive contamination with $^{99m}$Tc among medical personnel of nuclear medicine facilities using generally available respiratory tract protection systems. During the current research project, four respiratory tract protection systems were tested by estimation of $^{99m}$Tc activity levels in blood samples collected from medical personnel. Medical staf were equipped with a disposable surgical mask, a half mask with gas absorbers, a half mask with aerosol absorbers and a half mask with gas absorbers with added Petryanov flter. The presented results indicate that wearing only a disposable surgical mask may signifcantly reduce radioactive internal contamination among medical personnel and improve their safety in the workplace. The best results of reduced $^{99m}$Tc concentration in the blood were achieved by the use of a half mask with gas absorbers with added Pertryanov flters and a half mask with aerosol absorbers, where the reduction factors were estimated at 90% and 80%, respectively. Respiratory tract protection systems should become standard equipment for medical personnel performing ventilation–perfusion SPECT lung scans.
dc.affiliationpl
Wydział Nauk o Zdrowiu
dc.affiliationpl
Wydział Lekarski : Instytut Kardiologii
dc.affiliationpl
Wydział Fizyki, Astronomii i Informatyki Stosowanej : Instytut Fizyki im. Mariana Smoluchowskiego
dc.cm.date
2022-12-18T23:17:58Z
dc.cm.idpl
110610
dc.cm.idOmegapl
UJCM05bb87bd3c914fa6a907dc3893e88100
dc.contributor.authorpl
Brudecki, Kamil
dc.contributor.authorpl
Borkowska, Eliza - 216315
dc.contributor.authorpl
Gorzkiewicz, Krzysztof
dc.contributor.authorpl
Kostkiewicz, Magdalena - 130307
dc.contributor.authorpl
Misiak, Ryszard
dc.contributor.authorpl
Mróz, Tomasz - 395056
dc.contributor.authorpl
Nalichowska, Ewa
dc.date.accessionpl
2022-12-16
dc.date.accessioned
2022-12-18T23:17:58Z
dc.date.available
2022-12-18T23:17:58Z
dc.date.issuedpl
2022
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.additionalpl
Online First 2022-11-24
dc.description.numberpl
1
dc.description.physicalpl
5061-5065
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
331
dc.identifier.doipl
10.1007/s10967-022-08639-w
dc.identifier.eissnpl
1588-2780
dc.identifier.issnpl
0236-5731
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/304878
dc.identifier.weblinkpl
https://link.springer.com/article/10.1007/s10967-022-08639-w
dc.languagepl
eng
dc.language.containerpl
eng
dc.pbn.affiliation
Dziedzina nauk medycznych i nauk o zdrowiu : nauki medyczne
dc.rights*
Udzielam licencji. Uznanie autorstwa 4.0 Międzynarodowa
dc.rights.licence
CC-BY
dc.rights.uri*
http://creativecommons.org/licenses/by/4.0/legalcode.pl
dc.share.type
Otwarte czasopismo
dc.subject.enpl
$^{99m}$Tc
dc.subject.enpl
internal contamination
dc.subject.enpl
medical personnel
dc.subject.enpl
blood
dc.subject.enpl
lung
dc.subject.enpl
perfusion
dc.subject.enpl
ventilation
dc.subject.enpl
scintigraphy
dc.subtypepl
Article
dc.titlepl
Reduction in radioactive internal contamination by 99mTc among medical personnel in nuclear medicine facilities with the use of respiratory tract protection measures
dc.title.journalpl
Journal of Radioanalytical and Nuclear Chemistry
dc.typepl
JournalArticle
dspace.entity.type
Publication

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
2
Views per month
Views per city
Innsbruck
1
Downloads
borkowska_kostkiewicz_mroz_et-al_reduction_in_radioactive_internal_contamination_2022.pdf
9