The SIDDHARTA-2 calibration method for high precision kaonic atoms x-ray spectroscopy measurements

2022
journal article
article
17
dc.abstract.enThe SIDDHARTA-2 experiment at the DAΦNE collider aims to perform the first kaonic deuterium x-ray transitions to the fundamental level measurement, with a systematic error at the level of a few eV. To achieve this challenging goal the experimental apparatus is equipped with 384 Silicon Drift Detectors (SDDs) distributed around its cryogenic gaseous target. The SDDs developed by the SIDDHARTA-2 collaboration are suitable for high precision kaonic atoms spectroscopy, thanks to their high energy and time resolutions combined with their radiation hardness. The energy response of each detector must be calibrated and monitored to keep the systematic error, due to processes such as gain fluctuations, at the level of 2–3 eV. This paper presents the SIDDHARTA-2 calibration method which was optimized during the preliminary phase of the experiment in the real background conditions of the DAΦNE collider, which is a fundamental tool to guarantee the high precision spectroscopic performances of the system over long periods of data taking, as that required for the kaonic deuterium measurement.pl
dc.affiliationWydział Fizyki, Astronomii i Informatyki Stosowanej : Instytut Fizyki im. Mariana Smoluchowskiegopl
dc.contributor.authorSgaramella, F.pl
dc.contributor.authorMiliucci, M.pl
dc.contributor.authorBazzi, M.pl
dc.contributor.authorBosnar, D.pl
dc.contributor.authorBragadireanu, M.pl
dc.contributor.authorCarminati, M.pl
dc.contributor.authorCargnelli, M.pl
dc.contributor.authorClozza, A.pl
dc.contributor.authorDeda, G.pl
dc.contributor.authorDe Paolis, L.pl
dc.contributor.authorDel Grande, R.pl
dc.contributor.authorFiorini, C.pl
dc.contributor.authorGuaraldo, C.pl
dc.contributor.authorIliescu, M.pl
dc.contributor.authorIwasaki, M.pl
dc.contributor.authorKing, P.pl
dc.contributor.authorLevi Sandri, P.pl
dc.contributor.authorMarton, J.pl
dc.contributor.authorMoskal, Paweł - 100401 pl
dc.contributor.authorNapolitano, F.pl
dc.contributor.authorNiedźwiecki, Szymon - 115136 pl
dc.contributor.authorPiscicchia, K.pl
dc.contributor.authorScordo, A.pl
dc.contributor.authorShi, H.pl
dc.contributor.authorSilarski, Michał - 103624 pl
dc.contributor.authorSirghi, D.pl
dc.contributor.authorSirghi, F.pl
dc.contributor.authorSkurzok, Magdalena - 106557 pl
dc.contributor.authorSpallone, A.pl
dc.contributor.authorTüchler, M.pl
dc.contributor.authorZmeskal, J.pl
dc.contributor.authorCurceanu, C.pl
dc.date.accessioned2023-02-09T11:22:34Z
dc.date.available2023-02-09T11:22:34Z
dc.date.issued2022pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.number11pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume97pl
dc.identifier.articleid114002pl
dc.identifier.doi10.1088/1402-4896/ac95dapl
dc.identifier.eissn1402-4896pl
dc.identifier.issn0031-8949pl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/307511
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa 4.0 Międzynarodowa*
dc.rights.licenceCC-BY
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/legalcode.pl*
dc.share.typeinne
dc.subject.ensilicon drift detectorspl
dc.subject.enx-ray spectroscopypl
dc.subject.enSIDDHARTA-2pl
dc.subtypeArticlepl
dc.titleThe SIDDHARTA-2 calibration method for high precision kaonic atoms x-ray spectroscopy measurementspl
dc.title.journalPhysica Scriptapl
dc.typeJournalArticlepl
dspace.entity.typePublication
dc.abstract.enpl
The SIDDHARTA-2 experiment at the DAΦNE collider aims to perform the first kaonic deuterium x-ray transitions to the fundamental level measurement, with a systematic error at the level of a few eV. To achieve this challenging goal the experimental apparatus is equipped with 384 Silicon Drift Detectors (SDDs) distributed around its cryogenic gaseous target. The SDDs developed by the SIDDHARTA-2 collaboration are suitable for high precision kaonic atoms spectroscopy, thanks to their high energy and time resolutions combined with their radiation hardness. The energy response of each detector must be calibrated and monitored to keep the systematic error, due to processes such as gain fluctuations, at the level of 2–3 eV. This paper presents the SIDDHARTA-2 calibration method which was optimized during the preliminary phase of the experiment in the real background conditions of the DAΦNE collider, which is a fundamental tool to guarantee the high precision spectroscopic performances of the system over long periods of data taking, as that required for the kaonic deuterium measurement.
dc.affiliationpl
Wydział Fizyki, Astronomii i Informatyki Stosowanej : Instytut Fizyki im. Mariana Smoluchowskiego
dc.contributor.authorpl
Sgaramella, F.
dc.contributor.authorpl
Miliucci, M.
dc.contributor.authorpl
Bazzi, M.
dc.contributor.authorpl
Bosnar, D.
dc.contributor.authorpl
Bragadireanu, M.
dc.contributor.authorpl
Carminati, M.
dc.contributor.authorpl
Cargnelli, M.
dc.contributor.authorpl
Clozza, A.
dc.contributor.authorpl
Deda, G.
dc.contributor.authorpl
De Paolis, L.
dc.contributor.authorpl
Del Grande, R.
dc.contributor.authorpl
Fiorini, C.
dc.contributor.authorpl
Guaraldo, C.
dc.contributor.authorpl
Iliescu, M.
dc.contributor.authorpl
Iwasaki, M.
dc.contributor.authorpl
King, P.
dc.contributor.authorpl
Levi Sandri, P.
dc.contributor.authorpl
Marton, J.
dc.contributor.authorpl
Moskal, Paweł - 100401
dc.contributor.authorpl
Napolitano, F.
dc.contributor.authorpl
Niedźwiecki, Szymon - 115136
dc.contributor.authorpl
Piscicchia, K.
dc.contributor.authorpl
Scordo, A.
dc.contributor.authorpl
Shi, H.
dc.contributor.authorpl
Silarski, Michał - 103624
dc.contributor.authorpl
Sirghi, D.
dc.contributor.authorpl
Sirghi, F.
dc.contributor.authorpl
Skurzok, Magdalena - 106557
dc.contributor.authorpl
Spallone, A.
dc.contributor.authorpl
Tüchler, M.
dc.contributor.authorpl
Zmeskal, J.
dc.contributor.authorpl
Curceanu, C.
dc.date.accessioned
2023-02-09T11:22:34Z
dc.date.available
2023-02-09T11:22:34Z
dc.date.issuedpl
2022
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.numberpl
11
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
97
dc.identifier.articleidpl
114002
dc.identifier.doipl
10.1088/1402-4896/ac95da
dc.identifier.eissnpl
1402-4896
dc.identifier.issnpl
0031-8949
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/307511
dc.languagepl
eng
dc.language.containerpl
eng
dc.rights*
Udzielam licencji. Uznanie autorstwa 4.0 Międzynarodowa
dc.rights.licence
CC-BY
dc.rights.uri*
http://creativecommons.org/licenses/by/4.0/legalcode.pl
dc.share.type
inne
dc.subject.enpl
silicon drift detectors
dc.subject.enpl
x-ray spectroscopy
dc.subject.enpl
SIDDHARTA-2
dc.subtypepl
Article
dc.titlepl
The SIDDHARTA-2 calibration method for high precision kaonic atoms x-ray spectroscopy measurements
dc.title.journalpl
Physica Scripta
dc.typepl
JournalArticle
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
1
Views per month
Views per city
Krakow
1
Downloads
moskal_niedzwiecki_silarski_skurzok_et-al_the_siddharta-2_calibration_method_fot_high_precision_2022.pdf
7