Simple view
Full metadata view
Authors
Statistics
Application of probit method for the elastographic evaluation of venous obliterating material after sclerotherapy procedure
deep vein thrombosis
ultrasonography
imaging
polidocanol
Bibliogr. s. e14-e15
Purpose: Status after sclerotherapy constitutes a good clinical model for venous thrombosis with known age. The aim of this study was to compare elastographic parameters of material obliterating the great saphenous vein at 7-21 days after polidocanol sclerotherapy. Material and methods: The study included 60 patients subjected to sclerotherapy due to venous insufficiency (45 women and 15 men, mean age 51.2 ± 14.7 years, range 27-77 years). Elastographic parameters of obliterating material: total area of vessel cross-section (mm2), relative areas (%) covered by tissues with highest, intermediate, and lowest elasticity, were determined 7 ± 1, 14 ± 2, and 21 ± 2 days post-sclerotherapy, respectively. Mean time to partial and complete organisation of the obliterating material was estimated during probit regression analysis. Results: The relative area of vessel cross-section covered by tissues with the lowest elasticity underwent a statistically significant enlargement, either between the first and the second (Z = 6.725, p < 0.001) or between the second and the third control visit (Z = 6.717, p < 0.001). This corresponded to a change in the structure of the obliterating material from elastic during the first visit (in all patients) to mixed (fibro-elastic) or fibrous during the third visit (71.7% and 28.3% of patients, respectively). Mean time after which the obliterating material reached mixed and fibrous structure on elastographic images was estimated at 14.3 days and > 21 days, respectively. Conclusions: Ultrasound elastography may accurately reflect the age of venous thrombosis in polidocanol sclerotherapy model. Mixed, fibro-elastic structure of a 14-day-old obliterating material visualised by elastography probably corresponds with chronic thrombus.
cris.lastimport.wos | 2024-04-10T02:53:23Z | |
dc.abstract.en | Purpose: Status after sclerotherapy constitutes a good clinical model for venous thrombosis with known age. The aim of this study was to compare elastographic parameters of material obliterating the great saphenous vein at 7-21 days after polidocanol sclerotherapy. Material and methods: The study included 60 patients subjected to sclerotherapy due to venous insufficiency (45 women and 15 men, mean age 51.2 ± 14.7 years, range 27-77 years). Elastographic parameters of obliterating material: total area of vessel cross-section (mm2), relative areas (%) covered by tissues with highest, intermediate, and lowest elasticity, were determined 7 ± 1, 14 ± 2, and 21 ± 2 days post-sclerotherapy, respectively. Mean time to partial and complete organisation of the obliterating material was estimated during probit regression analysis. Results: The relative area of vessel cross-section covered by tissues with the lowest elasticity underwent a statistically significant enlargement, either between the first and the second (Z = 6.725, p < 0.001) or between the second and the third control visit (Z = 6.717, p < 0.001). This corresponded to a change in the structure of the obliterating material from elastic during the first visit (in all patients) to mixed (fibro-elastic) or fibrous during the third visit (71.7% and 28.3% of patients, respectively). Mean time after which the obliterating material reached mixed and fibrous structure on elastographic images was estimated at 14.3 days and > 21 days, respectively. Conclusions: Ultrasound elastography may accurately reflect the age of venous thrombosis in polidocanol sclerotherapy model. Mixed, fibro-elastic structure of a 14-day-old obliterating material visualised by elastography probably corresponds with chronic thrombus. | pl |
dc.contributor.author | Paluch, Łukasz | pl |
dc.contributor.author | Nitek, Żaneta | pl |
dc.contributor.author | Sklinda, Katarzyna | pl |
dc.contributor.author | Noszczyk, Bartłomiej | pl |
dc.contributor.author | Walecki, Jerzy | pl |
dc.date.accessioned | 2019-02-19T07:45:58Z | |
dc.date.available | 2019-02-19T07:45:58Z | |
dc.date.issued | 2019 | pl |
dc.date.openaccess | 0 | |
dc.description.accesstime | w momencie opublikowania | |
dc.description.additional | Bibliogr. s. e14-e15 | pl |
dc.description.physical | e9-e15 | pl |
dc.description.version | ostateczna wersja wydawcy | |
dc.description.volume | 84 | pl |
dc.identifier.doi | 10.5114/pjr.2019.81178 | pl |
dc.identifier.eissn | 1899-0967 | pl |
dc.identifier.issn | 1733-134X | pl |
dc.identifier.project | ROD UJ / OP | pl |
dc.identifier.uri | https://ruj.uj.edu.pl/xmlui/handle/item/68676 | |
dc.language | eng | pl |
dc.language.container | eng | pl |
dc.rights | Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa | * |
dc.rights.licence | CC-BY-NC-ND | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl | * |
dc.share.type | otwarte czasopismo | |
dc.subject.en | deep vein thrombosis | pl |
dc.subject.en | ultrasonography | pl |
dc.subject.en | imaging | pl |
dc.subject.en | polidocanol | pl |
dc.subtype | Article | pl |
dc.title | Application of probit method for the elastographic evaluation of venous obliterating material after sclerotherapy procedure | pl |
dc.title.journal | Polish Journal of Radiology | pl |
dc.type | JournalArticle | pl |
dspace.entity.type | Publication |
* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.
Views
8
Views per month
Views per city
Downloads
Open Access