dc.abstract.enBackground: The study was aimed at the development of parameters that could be used as predictors of vertebral strength. Proposed parameters describing vertebral geometry and/or shape can be established on the basis of routine spine roentgenograms, making roentgenography a novel tool for vertebral fracture risk assessment in the future. Material/Methods: 20 human cadaveric L3 vertebrae were included in the study. Dual-energy X-ray absorptiometry (DXA) was used for an assessment of bone mineral density (BMD). Quantitative computed tomography (QCT) was performed to measure the volumetric bone density as the most reliable parameter in vertebral fracture risk assessment. Geometrical measurements were performed on the basis of high quality and high resolution computer tomography 3-dimensional images. Biomechanical tests were performed to measure vertebral strength. Two parameters were defined on the basis of extensive research: the ratio between vertebral base area and its height (A/H), and the ratio of vertebral coronal width to coronal height (W/H). Correlations between vertebral mechanical strength - its BMD, QCT density, A/H and W/H were calculated. Results: The best correlation to bone durability was achieved for QCT density (r=0.882), while correlation strength for BMD (r=0.779) and A/H (r=-0.773) were comparable. W/H correlated better than BMD to mechanical strength (-0.788). Conclusions: Geometrical parameters of vertebrae potentially measured on spine radiograms could be used as predictors of vertebral durability. The calculated correlation coefficients suggest that one of the proposed parameters works better than the commonly used BMD.pl
dc.affiliationWydział Fizyki, Astronomii i Informatyki Stosowanej : Instytut Fizyki im. Mariana Smoluchowskiegopl
dc.affiliationWydział Lekarski : Zakład Biofizykipl
dc.cm.id59242
dc.contributor.authorTatoń, Grzegorz - 133654 pl
dc.contributor.authorRokita, Eugeniusz - 133291 pl
dc.contributor.authorWróbel, Andrzej - 132782 pl
dc.date.accessioned2017-09-04T17:49:27Z
dc.date.available2017-09-04T17:49:27Z
dc.date.issued2013pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. 18pl
dc.description.number2pl
dc.description.physical15-18pl
dc.description.points7pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume78pl
dc.identifier.doi10.12659/PJR.883942pl
dc.identifier.eissn1899-0967pl
dc.identifier.issn1733-134Xpl
dc.identifier.projectROD UJ / Ppl
dc.identifier.urihttp://ruj.uj.edu.pl/xmlui/handle/item/43799
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 3.0 Polska*
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/pl/legalcode*
dc.share.typeotwarte czasopismo
dc.subject.enBMDpl
dc.subject.enDXApl
dc.subject.enQCTpl
dc.subject.envertebral strengthpl
dc.subject.envertebral biomechanicspl
dc.subtypeArticlepl
dc.titleApplication of geometrical measurements in the assessment of vertebral strengthpl
dc.title.journalPolish Journal of Radiologypl
dc.typeJournalArticlepl
dspace.entity.typePublication

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
0
Views per month
Downloads
taton_rokita_wrobel_application_of_geometrical_measurements_in_the_assessment_2013.pdf
1