Simple view
Full metadata view
Authors
Statistics
Reconstruction of hit time and hit position of annihilation quanta in the J-PET detector using the Mahalanobis distance
J-PET detector
Mahalanobis distance
time resolution
threshold levels
Autorka Daria Kisielewska podpisana jako Daria Kamińska.
The J-PET detector being developed at Jagiellonian University, is a Positron Emission Tomograph composed of the long strips of polymer scintillators. At the same time it is a detector system which will be used for studies of the decays of positronium atoms. The shape of photomultiplier signals depends on the hit-time and hit-position of the gamma quantum. In order to take advantage of this fact a dedicated sampling front-end electronics which enables to sample signals in voltage domain with the time precision of about 20 ps and novel reconstruction method based on the comparison of examined signal with the model signals stored in the library has been developed. As a measure of the similarity we use the Mahalanobis distance. The achievable position and time-resolution depends on number and values of the threshold levels at which the signal is sampled. A reconstruction method, as well as preliminary results are presented and discussed.
cris.lastimport.wos | 2024-04-09T23:40:34Z | |
dc.abstract.en | The J-PET detector being developed at Jagiellonian University, is a Positron Emission Tomograph composed of the long strips of polymer scintillators. At the same time it is a detector system which will be used for studies of the decays of positronium atoms. The shape of photomultiplier signals depends on the hit-time and hit-position of the gamma quantum. In order to take advantage of this fact a dedicated sampling front-end electronics which enables to sample signals in voltage domain with the time precision of about 20 ps and novel reconstruction method based on the comparison of examined signal with the model signals stored in the library has been developed. As a measure of the similarity we use the Mahalanobis distance. The achievable position and time-resolution depends on number and values of the threshold levels at which the signal is sampled. A reconstruction method, as well as preliminary results are presented and discussed. | pl |
dc.affiliation | Wydział Fizyki, Astronomii i Informatyki Stosowanej : Instytut Fizyki im. Mariana Smoluchowskiego | pl |
dc.affiliation | Wydział Fizyki, Astronomii i Informatyki Stosowanej : Zakład Technologii Gier | pl |
dc.contributor.author | Gupta-Sharma, Neha - 235987 | pl |
dc.contributor.author | Silarski, Michał - 103624 | pl |
dc.contributor.author | Bednarski, Tomasz - 115868 | pl |
dc.contributor.author | Białas, Piotr - 127296 | pl |
dc.contributor.author | Czerwiński, Eryk - 102850 | pl |
dc.contributor.author | Gajos, Aleksander - 164087 | pl |
dc.contributor.author | Gorgol, Marek | pl |
dc.contributor.author | Jasińska, Bożena | pl |
dc.contributor.author | Kisielewska, Daria - 179828 | pl |
dc.contributor.author | Kapłon, Łukasz - 115081 | pl |
dc.contributor.author | Korcyl, Grzegorz - 107362 | pl |
dc.contributor.author | Kowalski, Paweł | pl |
dc.contributor.author | Kozik, Tomasz - 129362 | pl |
dc.contributor.author | Krzemień, Wojciech - 135126 | pl |
dc.contributor.author | Kubicz, Ewelina - 177092 | pl |
dc.contributor.author | Niedźwiecki, Szymon - 115136 | pl |
dc.contributor.author | Pałka, Marek - 214237 | pl |
dc.contributor.author | Raczyński, Lech | pl |
dc.contributor.author | Rudy, Zbigniew - 100004 | pl |
dc.contributor.author | Rundel, Oleksandr - 249228 | pl |
dc.contributor.author | Słomski, Artur - 109394 | pl |
dc.contributor.author | Strzelecki, Adam - 182201 | pl |
dc.contributor.author | Wieczorek, Anna - 163447 | pl |
dc.contributor.author | Wiślicki, Wojciech | pl |
dc.contributor.author | Zieliński, Marcin - 124902 | pl |
dc.contributor.author | Zgardzińska, Bożena | pl |
dc.contributor.author | Moskal, Paweł - 100401 | pl |
dc.date.accession | 2015-11-20 | pl |
dc.date.accessioned | 2015-11-20T15:07:14Z | |
dc.date.available | 2015-11-20T15:07:14Z | |
dc.date.issued | 2015 | pl |
dc.date.openaccess | 0 | |
dc.description.accesstime | w momencie opublikowania | |
dc.description.additional | Autorka Daria Kisielewska podpisana jako Daria Kamińska. | pl |
dc.description.admin | [AU] Krzemień, Wojciech [SAP12018791] | |
dc.description.number | 4 | pl |
dc.description.physical | 765-769 | pl |
dc.description.publication | 0,3 | pl |
dc.description.version | ostateczna wersja wydawcy | |
dc.description.volume | 60 | pl |
dc.identifier.doi | 10.1515/nuka-2015-0138 | pl |
dc.identifier.eissn | 1508-5791 | pl |
dc.identifier.issn | 0029-5922 | pl |
dc.identifier.project | ROD UJ / P | pl |
dc.identifier.uri | http://ruj.uj.edu.pl/xmlui/handle/item/16999 | |
dc.identifier.weblink | http://www.nukleonika.pl/www/back/full/vol60_2015/v60n4p765f.pdf | pl |
dc.language | eng | pl |
dc.language.container | eng | pl |
dc.rights | Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 3.0 Polska | * |
dc.rights.licence | CC-BY-NC-ND | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/legalcode | * |
dc.share.type | otwarte czasopismo | |
dc.subject.en | J-PET detector | pl |
dc.subject.en | Mahalanobis distance | pl |
dc.subject.en | time resolution | pl |
dc.subject.en | threshold levels | pl |
dc.subtype | Article | pl |
dc.title | Reconstruction of hit time and hit position of annihilation quanta in the J-PET detector using the Mahalanobis distance | pl |
dc.title.journal | Nukleonika | pl |
dc.title.volume | Proceedings of the 42nd Polish Seminar on Positron Annihilation Lublin, Poland, 29 June -1 July 2015 | pl |
dc.type | JournalArticle | pl |
dspace.entity.type | Publication |
* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.
Views
34
Views per month
Views per city
Downloads
Open Access