An estimation of the goiters by means of ultrasonography and scintigraphy (SPECT) using ^{99m}Tc

2009
journal article
article
dc.abstract.enBackground: The thyroid is the large, single and usually asymmetric endocrine gland consisting of two lateral lobes joined by the isthmus. A thyroid volume over 18 ml in females and 25 ml in males is called goiter. Among the methods evaluating the volume of the thyroid we can submit ultrasonography (US) and scintigraphy (SPECT). The aim of the study was to estimate the volume of goiters by means of US and ^{99m}Tc-SPECT. Material/Methods: A group of 80 patients were examined. Patients were divided into two groups. Group A contained 50 patients (43 females, 7 males) with goiter, where the volume of the thyroid was compared with the use of US and ^{99m}Tc-SPECT. Group B contained 30 patients (23 females, 7 males) with a normal volume of the thyroid gland as shown by US and ^{99m}Tc-SPECT. US of the thyroid gland was made by means of the ALOKA SSD 500 device, with a linear head of 7.5 MHz. ^{99m}Tc-SPECT was made by means of a one head gammacamera Diacam with a low energy high resolution collimator (LEHR). Results: In both groups similar results were obtained. In the group A, the average volume of the goiter was 29.83 ml in US and 33.27 ml in SPECT (p<0.001). In the control group B the average volume of the thyroid gland was 16 ml and 18.18 ml (p<0.001), respectively Conclusions: The thyroid volume estimated by ^{99m}Tc-SPECT was significantly higher than that by US, in both investigated and control groups, and in females and males.pl
dc.contributor.authorGierach, Marcinpl
dc.contributor.authorGierach, Joannapl
dc.contributor.authorPilecki, Stanisławpl
dc.contributor.authorPujanek, Małgorzatapl
dc.contributor.authorJunik, Romanpl
dc.contributor.authorLasek, Władysławpl
dc.date.accession2018-12-10pl
dc.date.accessioned2018-12-10T11:42:33Z
dc.date.available2018-12-10T11:42:33Z
dc.date.issued2009pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. 38pl
dc.description.number2pl
dc.description.physical35-38pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume74pl
dc.identifier.articleid878390pl
dc.identifier.eissn1899-0967pl
dc.identifier.issn1733-134Xpl
dc.identifier.projectROD UJ / OPpl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/63144
dc.identifier.weblinkhttp://archiwum.polradiol.com/abstract/index/idArt/878390pl
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa*
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl*
dc.share.typeotwarte czasopismo
dc.subject.engoiterpl
dc.subject.enUSpl
dc.subject.enSPECTpl
dc.subject.en^{99m}Tcpl
dc.subtypeArticlepl
dc.titleAn estimation of the goiters by means of ultrasonography and scintigraphy (SPECT) using ^{99m}Tcpl
dc.title.journalPolish Journal of Radiologypl
dc.typeJournalArticlepl
dspace.entity.typePublication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
0
Views per month