Simple view
Full metadata view
Authors
Statistics
Percutaneous extraction of a coiled, 20-year-old lead in a patient with cardiac resynchronization therapy
percutaneous lead extraction
permanent pacing
A 61-year-old patient with a 20-year history of permanent pacemaker implantation and half-a-year cardiac resynchronization therapy using a left ventricular lead placed via surgical approach was admitted for extraction of an old coiled right ventricular lead, which triggered ventricular arrhythmia and created a risk of pulmonary embolism. The lead was extracted via the left femoral vein in two stages: untying a loop on the lead using a pig-tail catheter and Dotter basket followed by traction and dissection of adhesions using a Byrd dilator sheath. Dissection of the old lead from the active right ventricular one posed special technical problems.
dc.abstract.en | A 61-year-old patient with a 20-year history of permanent pacemaker implantation and half-a-year cardiac resynchronization therapy using a left ventricular lead placed via surgical approach was admitted for extraction of an old coiled right ventricular lead, which triggered ventricular arrhythmia and created a risk of pulmonary embolism. The lead was extracted via the left femoral vein in two stages: untying a loop on the lead using a pig-tail catheter and Dotter basket followed by traction and dissection of adhesions using a Byrd dilator sheath. Dissection of the old lead from the active right ventricular one posed special technical problems. | pl |
dc.affiliation | Wydział Lekarski : Instytut Kardiologii | pl |
dc.contributor.author | Małecka, Barbara - 130836 | pl |
dc.contributor.author | Kutarski, Andrzej | pl |
dc.contributor.author | Bednarek, Jacek - 128713 | pl |
dc.contributor.author | Ząbek, Andrzej | pl |
dc.contributor.author | Lelakowski, Jacek - 130641 | pl |
dc.date.accession | 2020-12-15 | pl |
dc.date.accessioned | 2020-12-15T15:51:22Z | |
dc.date.available | 2020-12-15T15:51:22Z | |
dc.date.issued | 2008 | pl |
dc.date.openaccess | 0 | |
dc.description.accesstime | w momencie opublikowania | |
dc.description.additional | Bibliogr. s. 375 | pl |
dc.description.number | 4 | pl |
dc.description.physical | 371-375 | pl |
dc.description.version | ostateczna wersja wydawcy | |
dc.description.volume | 15 | pl |
dc.identifier.eissn | 1898-018X | pl |
dc.identifier.issn | 1897-5593 | pl |
dc.identifier.project | ROD UJ / OP | pl |
dc.identifier.uri | https://ruj.uj.edu.pl/xmlui/handle/item/258933 | |
dc.identifier.weblink | https://journals.viamedica.pl/cardiology_journal/article/view/21592 | pl |
dc.language | eng | pl |
dc.language.container | eng | pl |
dc.rights | Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa | * |
dc.rights.licence | CC-BY-NC-ND | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl | * |
dc.share.type | otwarte czasopismo | |
dc.subject.en | percutaneous lead extraction | pl |
dc.subject.en | permanent pacing | pl |
dc.subtype | Article | pl |
dc.title | Percutaneous extraction of a coiled, 20-year-old lead in a patient with cardiac resynchronization therapy | pl |
dc.title.journal | Cardiology Journal | pl |
dc.type | JournalArticle | pl |
dspace.entity.type | Publication |
* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.
Views
0
Views per month
Open Access