Test detektorów dla polarymetru w pomiarze elektrycznego momentu dipolowego

licenciate
dc.abstract.enWithin the thesis a calorimeter containing four detectors with LYSO crystals and VETOmodules with plastic sincilators and amplifiers was build. VETO modules was used to ob-serve escaping particles from detector. This was used to study energy resolution of a classicfotomultipliers and a silicon photomultipliers (SiPM). Mesurements was preformed using adeuteron particles beam with energy 270 MeV . Mesured resolution are 1.37% for the classicphotomultiplier an 0.83% for the silicone phtomultiplier. Results shows that using the siliconephtomultiplier is more efficien. However it should be checked if difference between resolutionswasn’t caused by worse optical contact between classic photomulriplier with scincilator. Alsoamplifier characteristic of VETO module was preformed. Amplifiers proved to be nonlinear inboth amplitude and surface area.pl
dc.abstract.plW ramach pracy zbudowano kalorymetr składający się z czterech detektorów z kryształami LYSO, moduły VETO składające się ze scyntylatorów plastikowych oraz wzmacniacz sygnałów dla detektorów VETO. Moduły VETO wraz z wzmacniaczami posłużyły do obserwacji uciekających z kryształów cząstek.Badano energetyczną zdolność rozdzielczą fotopowielaczy klasycznych oraz krzemowych (SiPM). Pomiary przeprowadzono używając wiązki deuteronów o energii 270 MeV. Zmierzone energetyczne zdolności rozdzielcze wynoszą 1.37% dla fotopowielacza klasycznego oraz 0.83% dla fotopowielacza krzemowego. Wynik wskazuje iż bardziej korzystne jest użycie fotopowielacza krzemowego. Jakkolwiek należy sprawdzić czy różnica w zdolności rozdzielczej nie była spowodowana gorszym kontaktem optycznym fotopowielacza klasycznego ze scyntylatorem. Zbadano także charakterystykę wzmocnienia wzmacniaczy modułów VETO. Wzmacniacze te okazały się być nieliniowe zarówno dla mierzonej amplitudy jak i dla mierzonej powierzchni sygnału.pl
dc.affiliationWydział Fizyki, Astronomii i Informatyki Stosowanejpl
dc.areaobszar nauk ścisłychpl
dc.contributor.advisorMagiera, Andrzej - 102054 pl
dc.contributor.authorPopczak, Arkadiuszpl
dc.contributor.departmentbycodeUJK/WFAISpl
dc.contributor.reviewerMagiera, Andrzej - 102054 pl
dc.contributor.reviewerWrońska, Aleksandra - 102049 pl
dc.date.accessioned2020-07-26T23:11:36Z
dc.date.available2020-07-26T23:11:36Z
dc.date.submitted2017-10-19pl
dc.fieldofstudyfizyka teoretycznapl
dc.identifier.apddiploma-106462-160487pl
dc.identifier.projectAPD / Opl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/212777
dc.languagepolpl
dc.subject.enelectric, dipole, moment, photomultiplier, polarimeterpl
dc.subject.plelektryczny, moment, dipolowy, detektory, fotopowielcza, polarymetrpl
dc.titleTest detektorów dla polarymetru w pomiarze elektrycznego momentu dipolowegopl
dc.title.alternativeDetectors test for polarimeter in electric dipole moment mesurement.pl
dc.typelicenciatepl
dspace.entity.typePublication
dc.abstract.enpl
Within the thesis a calorimeter containing four detectors with LYSO crystals and VETOmodules with plastic sincilators and amplifiers was build. VETO modules was used to ob-serve escaping particles from detector. This was used to study energy resolution of a classicfotomultipliers and a silicon photomultipliers (SiPM). Mesurements was preformed using adeuteron particles beam with energy 270 MeV . Mesured resolution are 1.37% for the classicphotomultiplier an 0.83% for the silicone phtomultiplier. Results shows that using the siliconephtomultiplier is more efficien. However it should be checked if difference between resolutionswasn’t caused by worse optical contact between classic photomulriplier with scincilator. Alsoamplifier characteristic of VETO module was preformed. Amplifiers proved to be nonlinear inboth amplitude and surface area.
dc.abstract.plpl
W ramach pracy zbudowano kalorymetr składający się z czterech detektorów z kryształami LYSO, moduły VETO składające się ze scyntylatorów plastikowych oraz wzmacniacz sygnałów dla detektorów VETO. Moduły VETO wraz z wzmacniaczami posłużyły do obserwacji uciekających z kryształów cząstek.Badano energetyczną zdolność rozdzielczą fotopowielaczy klasycznych oraz krzemowych (SiPM). Pomiary przeprowadzono używając wiązki deuteronów o energii 270 MeV. Zmierzone energetyczne zdolności rozdzielcze wynoszą 1.37% dla fotopowielacza klasycznego oraz 0.83% dla fotopowielacza krzemowego. Wynik wskazuje iż bardziej korzystne jest użycie fotopowielacza krzemowego. Jakkolwiek należy sprawdzić czy różnica w zdolności rozdzielczej nie była spowodowana gorszym kontaktem optycznym fotopowielacza klasycznego ze scyntylatorem. Zbadano także charakterystykę wzmocnienia wzmacniaczy modułów VETO. Wzmacniacze te okazały się być nieliniowe zarówno dla mierzonej amplitudy jak i dla mierzonej powierzchni sygnału.
dc.affiliationpl
Wydział Fizyki, Astronomii i Informatyki Stosowanej
dc.areapl
obszar nauk ścisłych
dc.contributor.advisorpl
Magiera, Andrzej - 102054
dc.contributor.authorpl
Popczak, Arkadiusz
dc.contributor.departmentbycodepl
UJK/WFAIS
dc.contributor.reviewerpl
Magiera, Andrzej - 102054
dc.contributor.reviewerpl
Wrońska, Aleksandra - 102049
dc.date.accessioned
2020-07-26T23:11:36Z
dc.date.available
2020-07-26T23:11:36Z
dc.date.submittedpl
2017-10-19
dc.fieldofstudypl
fizyka teoretyczna
dc.identifier.apdpl
diploma-106462-160487
dc.identifier.projectpl
APD / O
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/212777
dc.languagepl
pol
dc.subject.enpl
electric, dipole, moment, photomultiplier, polarimeter
dc.subject.plpl
elektryczny, moment, dipolowy, detektory, fotopowielcza, polarymetr
dc.titlepl
Test detektorów dla polarymetru w pomiarze elektrycznego momentu dipolowego
dc.title.alternativepl
Detectors test for polarimeter in electric dipole moment mesurement.