Application of a metal ion-imprinted polymer based on salen-Cu complex to flow injection preconcentration and FAAS determination of copper

2008
journal article
article
71
cris.lastimport.wos2024-04-09T18:06:48Z
dc.abstract.enA new Cu(II)-imprinted polymer (Cu-IIP) for preconcentration of copper by liquid-solid extraction via flow injection technique has been proposed. Cu-IIP was obtained by copolymerization of salen-Cu(II) complex with styrene and divinylbenzene using suspension polymerization technique. Granules fracion of 60-80$\mu$m in diameter was used as a microcolumn packing. Cu(II) sorption was proved to be the most effective from solutions of pH 7, whereas similar elution effectiveness was observed when applying as eluents hydrochloric or nitric acid in the concentration range of 0.5-10% (v/v). The system exhibited good long-term stability and acid resistance. Batch sorbent capacity was found to be 0.11mmolg$^{-1}$ of a dry polymer. Enrichment factor (EF) for 30s loading time was 16. Preconcentration of Cu(II) and poten- tially interfering metal ions is strongly pH dependent. Examination of Cu(II) sorption in the presence of Pb(II), Cd(II), Zn(II) and Ag(I) showed significant influence of cadmium and zinc ions only and that was for the interferent concentrations above 0.5mgL$^{-1}$ (Cu-IIP mass of ca. 35mg). The interference effect was reduced with the sorbent mass increase. Fe(III) and Mn(II) ions, present in treated tap water in rel- atively high concentrations, did not interfere. Effective pH adjusting of the loaded solution in on-line mode, when applying diluted Clark-Lubs buffering solution, allowed accurate copper determination in tap water (compared to graphite furnace atomic absorption spectrometry, GFAAS) using standard addition or combination calibration method.pl
dc.affiliationWydział Chemii : Zakład Chemii Analitycznejpl
dc.affiliationWydział Chemii : Zakład Chemii Organicznejpl
dc.contributor.authorWalas, Stanisław - 132508 pl
dc.contributor.authorTelk, Anna - 156141 pl
dc.contributor.authorGawin, Marta - 161092 pl
dc.contributor.authorStrojny, Marcinpl
dc.contributor.authorMrowiec, Halina - 130778 pl
dc.contributor.authorTrzewik, Bartosz - 132433 pl
dc.date.accessioned2015-09-14T05:50:11Z
dc.date.available2015-09-14T05:50:11Z
dc.date.issued2008pl
dc.description.additionalNa publikacji autorka Telk Anna podpisana jako Tobiasz Anna.pl
dc.description.number1pl
dc.description.physical96-101pl
dc.description.volume76pl
dc.identifier.doi10.1016/j.talanta.2008.02.008pl
dc.identifier.eissn1873-3573pl
dc.identifier.issn0039-9140pl
dc.identifier.urihttp://ruj.uj.edu.pl/xmlui/handle/item/15602
dc.languageengpl
dc.language.containerengpl
dc.rightsDodaję tylko opis bibliograficzny*
dc.rights.licencebez licencji
dc.rights.uri*
dc.subtypeArticlepl
dc.titleApplication of a metal ion-imprinted polymer based on salen-Cu complex to flow injection preconcentration and FAAS determination of copperpl
dc.title.journalTalantapl
dc.typeJournalArticlepl
dspace.entity.typePublication

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
0
Views per month

No access

No Thumbnail Available