The use of a new generation self-expanding stent, Vascuflex SEC, for carotid artery stenting

2011
journal article
article
cris.lastimport.scopus2024-04-27T01:26:02Z
cris.lastimport.wos2024-04-09T20:24:21Z
dc.abstract.enBackground: Technological developments in the embolic protection device (EPD) and stent designs contribute significantly to the progress in endovascular management of carotid artery stenosis. Aim: To evaluate the safety and efficacy of carotid artery stenting (CAS) using a new generation self-expanding nitinol stent, Vascuflex SEC, with different types of embolic protection. Material and methods: Carotid artery stenting with Vascuflex SEC was performed in 50 consecutive patients (age 66.4 ±7.8 years, men 66%, symptomatic 40%) referred for the procedure after independent neurological consultation. Embolic protection device type was selected on the basis of atherosclerotic plaque morphology by duplex ultrasound and CT angiography. In a subset of patients (n = 20), we tested the feasibility of using intravascular ultrasound with virtual histology (IVUS-VH) to guide the EPD choice and final stent post-dilation. Proximal neuroprotection by flow reversal or temporary flow cessation was applied in 23 procedures (46%). Clinical evaluation was performed at discharge and at 30 days. Results: Procedural success was 100% and, in all cases, only one stent was implanted per patient/lesion. Direct stenting was performed in 20 patients (40%). Intraprocedural IVUS-VH was feasible and safe. Diameter stenosis was reduced from 84.1 ±7.5% to 9.1±7.7% (p < 0.001). There were two neurological events: one periprocedural ipsilateral minor stroke and one contralateral major stroke within 30 days. A closure device was used in 80% of patients and no access site complications occurred. Conclusions: In an unselected population referred for carotid revascularization, CAS with Vascuflex SEC stents is safe and effective. Lesion morphology-guided selection of EPD may contribute to the low complication rate.pl
dc.abstract.plWstęp: Zwiększenie bezpieczeństwa i stały rozwój zabiegów stentowania tętnic szyjnych (ang. carotid artery stenting, CAS) z zastosowaniem systemów protekcyjnych (ang. embolic protection device, EPD) jest możliwy dzięki postępowi technologicznemu stosowanych urządzeń. Cel: Ocena skuteczności i bezpieczeństwa CAS z zastosowaniem nowej generacji samorozprężalnych stentów nitinolowych Vascuflex SEC. Materiał i metody: Od stycznia do końca kwietnia 2010 r. zabiegi CAS z implantacją stentów samorozprężalnych Vascuflex SEC przeprowadzono u kolejnych 50 chorych (33 mężczyzn i 17 kobiet, średnia wieku 66,4 ±7,8 roku, objawy – 20 osób, tj. 40%). Przed zabiegiem u wszystkich chorych wykonano badanie ultrasonograficzne oraz angio-TK w celu określenia stopnia i morfologii zwężenia. W podgrupie 20 chorych wykonano ultrasonografię wewnątrznaczyniową (ang. intravascular ultrasound with virtual histology, IVUS-VH) w celu wstępnej selekcji EPD i oceny postdylatacji po CAS. Zabiegi CAS wykonano u wszystkich chorych z zastosowaniem EPD (protekcja proksymalna u 23 chorych – 46%). Chorych poddano ocenie bezpośrednio po zabiegu, w dniu wypisu i po 30 dniach. U 40 osób (80%) po zabiegu zastosowano urządzenia zamykające tętnicę udową w miejscu wkłucia. Wyniki: Uzyskano 100-procentową skuteczność zabiegów; u wszystkich chorych implantowano jeden stent. Stwierdzono istotne zmniejszenie stopnia zwężenia tętnicy szyjnej z 84,1 ±7,5% do 9,1 ±7,7%, p < 0,001. Badanie IVUS-VH wykonano bez powikłań. W trakcie obserwacji szpitalnej i 30-dniowej stwierdzono 2 (4%) incydenty neurologiczne (1 mały udar i 1 konralateralny duży udar). Nie odnotowano istotnych powikłań miejscowych w analizowanej grupie chorych. Wnioski: Zabiegi stentowania tętnic szyjnych z zastosowaniem nitinolowych stentów Vascuflex SEC są procedurą bezpieczną. Liczba powikłań okołozabiegowych i w 30-dniowej obserwacji nie przekracza wyznaczonych zaleceniami wartości. Na dobre wyniki stosowanych stentów może mieć wpływ odpowiedni dobór różnych czasowych urządzeń protekcyjnych mózgu.pl
dc.affiliationWydział Lekarski : Instytut Kardiologiipl
dc.affiliationWydział Lekarski : Instytut Pediatriipl
dc.contributor.authorOdrowąż-Pieniążek, Piotr - 133022 pl
dc.contributor.authorMusiałek, Piotr - 173944 pl
dc.contributor.authorTekieli, Łukaszpl
dc.contributor.authorDzierwa, Karolinapl
dc.contributor.authorMotyl, Rafałpl
dc.contributor.authorTrystuła, Mariusz - 356558 pl
dc.contributor.authorDura, Elżbietapl
dc.contributor.authorBrzychczy, Andrzejpl
dc.contributor.authorMachnik, Romanpl
dc.contributor.authorŻmudka, Krzysztof - 133948 pl
dc.contributor.authorPodolec, Piotr - 133185 pl
dc.date.accessioned2020-05-14T09:58:58Z
dc.date.available2020-05-14T09:58:58Z
dc.date.issued2011pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.number2 (24)pl
dc.description.physical105-110pl
dc.description.publication0,6pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume7pl
dc.identifier.doi10.5114/pwki.2011.23161pl
dc.identifier.eissn1897-4295pl
dc.identifier.issn1734-9338pl
dc.identifier.projectROD UJ / OPpl
dc.identifier.urihttps://ruj.uj.edu.pl/xmlui/handle/item/155868
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Na tych samych warunkach 4.0 Międzynarodowa*
dc.rights.licenceCC-BY-NC-SA
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/legalcode.pl*
dc.share.typeotwarte czasopismo
dc.subject.encarotid artery stenosispl
dc.subject.encarotid artery stentingpl
dc.subject.enself-expanding carotid stentspl
dc.subject.enopen-cell stent designpl
dc.subject.plzwężenie tętnic szyjnychpl
dc.subject.plangioplastyka tętnic szyjnychpl
dc.subject.plsamorozprężalne stenty otwartokomórkowepl
dc.subtypeArticlepl
dc.titleThe use of a new generation self-expanding stent, Vascuflex SEC, for carotid artery stentingpl
dc.title.alternativeZastosowanie nowej generacji samorozprężalnego stentu Vascuflex SEC do zabiegów stentowania tętnic szyjnychpl
dc.title.journalPostępy w Kardiologii Interwencyjnejpl
dc.typeJournalArticlepl
dspace.entity.typePublication
cris.lastimport.scopus
2024-04-27T01:26:02Z
cris.lastimport.wos
2024-04-09T20:24:21Z
dc.abstract.enpl
Background: Technological developments in the embolic protection device (EPD) and stent designs contribute significantly to the progress in endovascular management of carotid artery stenosis. Aim: To evaluate the safety and efficacy of carotid artery stenting (CAS) using a new generation self-expanding nitinol stent, Vascuflex SEC, with different types of embolic protection. Material and methods: Carotid artery stenting with Vascuflex SEC was performed in 50 consecutive patients (age 66.4 ±7.8 years, men 66%, symptomatic 40%) referred for the procedure after independent neurological consultation. Embolic protection device type was selected on the basis of atherosclerotic plaque morphology by duplex ultrasound and CT angiography. In a subset of patients (n = 20), we tested the feasibility of using intravascular ultrasound with virtual histology (IVUS-VH) to guide the EPD choice and final stent post-dilation. Proximal neuroprotection by flow reversal or temporary flow cessation was applied in 23 procedures (46%). Clinical evaluation was performed at discharge and at 30 days. Results: Procedural success was 100% and, in all cases, only one stent was implanted per patient/lesion. Direct stenting was performed in 20 patients (40%). Intraprocedural IVUS-VH was feasible and safe. Diameter stenosis was reduced from 84.1 ±7.5% to 9.1±7.7% (p < 0.001). There were two neurological events: one periprocedural ipsilateral minor stroke and one contralateral major stroke within 30 days. A closure device was used in 80% of patients and no access site complications occurred. Conclusions: In an unselected population referred for carotid revascularization, CAS with Vascuflex SEC stents is safe and effective. Lesion morphology-guided selection of EPD may contribute to the low complication rate.
dc.abstract.plpl
Wstęp: Zwiększenie bezpieczeństwa i stały rozwój zabiegów stentowania tętnic szyjnych (ang. carotid artery stenting, CAS) z zastosowaniem systemów protekcyjnych (ang. embolic protection device, EPD) jest możliwy dzięki postępowi technologicznemu stosowanych urządzeń. Cel: Ocena skuteczności i bezpieczeństwa CAS z zastosowaniem nowej generacji samorozprężalnych stentów nitinolowych Vascuflex SEC. Materiał i metody: Od stycznia do końca kwietnia 2010 r. zabiegi CAS z implantacją stentów samorozprężalnych Vascuflex SEC przeprowadzono u kolejnych 50 chorych (33 mężczyzn i 17 kobiet, średnia wieku 66,4 ±7,8 roku, objawy – 20 osób, tj. 40%). Przed zabiegiem u wszystkich chorych wykonano badanie ultrasonograficzne oraz angio-TK w celu określenia stopnia i morfologii zwężenia. W podgrupie 20 chorych wykonano ultrasonografię wewnątrznaczyniową (ang. intravascular ultrasound with virtual histology, IVUS-VH) w celu wstępnej selekcji EPD i oceny postdylatacji po CAS. Zabiegi CAS wykonano u wszystkich chorych z zastosowaniem EPD (protekcja proksymalna u 23 chorych – 46%). Chorych poddano ocenie bezpośrednio po zabiegu, w dniu wypisu i po 30 dniach. U 40 osób (80%) po zabiegu zastosowano urządzenia zamykające tętnicę udową w miejscu wkłucia. Wyniki: Uzyskano 100-procentową skuteczność zabiegów; u wszystkich chorych implantowano jeden stent. Stwierdzono istotne zmniejszenie stopnia zwężenia tętnicy szyjnej z 84,1 ±7,5% do 9,1 ±7,7%, p < 0,001. Badanie IVUS-VH wykonano bez powikłań. W trakcie obserwacji szpitalnej i 30-dniowej stwierdzono 2 (4%) incydenty neurologiczne (1 mały udar i 1 konralateralny duży udar). Nie odnotowano istotnych powikłań miejscowych w analizowanej grupie chorych. Wnioski: Zabiegi stentowania tętnic szyjnych z zastosowaniem nitinolowych stentów Vascuflex SEC są procedurą bezpieczną. Liczba powikłań okołozabiegowych i w 30-dniowej obserwacji nie przekracza wyznaczonych zaleceniami wartości. Na dobre wyniki stosowanych stentów może mieć wpływ odpowiedni dobór różnych czasowych urządzeń protekcyjnych mózgu.
dc.affiliationpl
Wydział Lekarski : Instytut Kardiologii
dc.affiliationpl
Wydział Lekarski : Instytut Pediatrii
dc.contributor.authorpl
Odrowąż-Pieniążek, Piotr - 133022
dc.contributor.authorpl
Musiałek, Piotr - 173944
dc.contributor.authorpl
Tekieli, Łukasz
dc.contributor.authorpl
Dzierwa, Karolina
dc.contributor.authorpl
Motyl, Rafał
dc.contributor.authorpl
Trystuła, Mariusz - 356558
dc.contributor.authorpl
Dura, Elżbieta
dc.contributor.authorpl
Brzychczy, Andrzej
dc.contributor.authorpl
Machnik, Roman
dc.contributor.authorpl
Żmudka, Krzysztof - 133948
dc.contributor.authorpl
Podolec, Piotr - 133185
dc.date.accessioned
2020-05-14T09:58:58Z
dc.date.available
2020-05-14T09:58:58Z
dc.date.issuedpl
2011
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.numberpl
2 (24)
dc.description.physicalpl
105-110
dc.description.publicationpl
0,6
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
7
dc.identifier.doipl
10.5114/pwki.2011.23161
dc.identifier.eissnpl
1897-4295
dc.identifier.issnpl
1734-9338
dc.identifier.projectpl
ROD UJ / OP
dc.identifier.uri
https://ruj.uj.edu.pl/xmlui/handle/item/155868
dc.languagepl
eng
dc.language.containerpl
eng
dc.rights*
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Na tych samych warunkach 4.0 Międzynarodowa
dc.rights.licence
CC-BY-NC-SA
dc.rights.uri*
http://creativecommons.org/licenses/by-nc-sa/4.0/legalcode.pl
dc.share.type
otwarte czasopismo
dc.subject.enpl
carotid artery stenosis
dc.subject.enpl
carotid artery stenting
dc.subject.enpl
self-expanding carotid stents
dc.subject.enpl
open-cell stent design
dc.subject.plpl
zwężenie tętnic szyjnych
dc.subject.plpl
angioplastyka tętnic szyjnych
dc.subject.plpl
samorozprężalne stenty otwartokomórkowe
dc.subtypepl
Article
dc.titlepl
The use of a new generation self-expanding stent, Vascuflex SEC, for carotid artery stenting
dc.title.alternativepl
Zastosowanie nowej generacji samorozprężalnego stentu Vascuflex SEC do zabiegów stentowania tętnic szyjnych
dc.title.journalpl
Postępy w Kardiologii Interwencyjnej
dc.typepl
JournalArticle
dspace.entity.type
Publication

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
0
Views per month