Three dimensional visualisation and morphometry of bone samples studied in microcomputed tomography (micro-CT)

2014
journal article
article
10
cris.lastimport.wos2024-04-10T01:57:20Z
dc.abstract.enThis article highlights the utility of micro-computed tomography (micro-CT) for characterisingmicroscale bone morphology. For this purpose we tested selected samplesof the human bones (Wormian bone, rib, lumbar vertebra) to reconstruct externaland internal morphological features. Selected bony samples were investigatedusing a micro-CT scanner (Skyscan 1172, N.V., Aartselaar, Belgium). The imageresolution of scans varied from 5 to 27 \mu m/pixel depending on the bone sample. We used CTvox software (by Skyscan) to perform volume rendering of the samples. Further, 3-dimensional geometrical models were reconstructed using the CTvol application. Such models enabled graphical distinction between osseouscomponents of various morphology and were used to visualise the Haversian canalsystem inside the compact bone of the rib. Applying a modified transfer functionfor volume rendering we presented the overall morphology of the Wormian boneand small vascular channels penetrating its interior. As an example of quantitativeanalysis based on micro-CT scans we compared the trabecular structure of thelumbar vertebrae with CTAn software. Significant differences in percent bonevolume (BV/TV) were determined. Micro-CT was found to be a very accurate andhelpful method to study small anatomical structures of the bones in micro scale.pl
dc.affiliationWydział Lekarski : Zakład Anatomiipl
dc.affiliationWydział Fizyki, Astronomii i Informatyki Stosowanej : Instytut Fizyki im. Mariana Smoluchowskiegopl
dc.cm.id68773
dc.contributor.authorLeszczyński, Bartosz - 183856 pl
dc.contributor.authorSkrzat, Janusz - 133416 pl
dc.contributor.authorKozerska, Magdalena - 104133 pl
dc.contributor.authorWróbel, Andrzej - 132782 pl
dc.contributor.authorWalocha, Jerzy - 133734 pl
dc.date.accessioned2015-05-19T08:36:41Z
dc.date.available2015-05-19T08:36:41Z
dc.date.issued2014pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.number4pl
dc.description.physical422-428pl
dc.description.points15pl
dc.description.publication0,5pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume73pl
dc.identifier.doi10.5603/FM.2014.0064pl
dc.identifier.eissn1644-3284pl
dc.identifier.issn0015-5659pl
dc.identifier.projectROD UJ / Ppl
dc.identifier.urihttp://ruj.uj.edu.pl/xmlui/handle/item/7385
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa*
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl*
dc.share.typeotwarte czasopismo
dc.source.integratorfalse
dc.subject.enbone microarchitecturepl
dc.subject.enmicro-computed tomographypl
dc.subject.enmicro-imagingpl
dc.subtypeArticlepl
dc.titleThree dimensional visualisation and morphometry of bone samples studied in microcomputed tomography (micro-CT)pl
dc.title.journalFolia Morphologicapl
dc.typeJournalArticlepl
dspace.entity.typePublication
cris.lastimport.wos
2024-04-10T01:57:20Z
dc.abstract.enpl
This article highlights the utility of micro-computed tomography (micro-CT) for characterisingmicroscale bone morphology. For this purpose we tested selected samplesof the human bones (Wormian bone, rib, lumbar vertebra) to reconstruct externaland internal morphological features. Selected bony samples were investigatedusing a micro-CT scanner (Skyscan 1172, N.V., Aartselaar, Belgium). The imageresolution of scans varied from 5 to 27 \mu m/pixel depending on the bone sample. We used CTvox software (by Skyscan) to perform volume rendering of the samples. Further, 3-dimensional geometrical models were reconstructed using the CTvol application. Such models enabled graphical distinction between osseouscomponents of various morphology and were used to visualise the Haversian canalsystem inside the compact bone of the rib. Applying a modified transfer functionfor volume rendering we presented the overall morphology of the Wormian boneand small vascular channels penetrating its interior. As an example of quantitativeanalysis based on micro-CT scans we compared the trabecular structure of thelumbar vertebrae with CTAn software. Significant differences in percent bonevolume (BV/TV) were determined. Micro-CT was found to be a very accurate andhelpful method to study small anatomical structures of the bones in micro scale.
dc.affiliationpl
Wydział Lekarski : Zakład Anatomii
dc.affiliationpl
Wydział Fizyki, Astronomii i Informatyki Stosowanej : Instytut Fizyki im. Mariana Smoluchowskiego
dc.cm.id
68773
dc.contributor.authorpl
Leszczyński, Bartosz - 183856
dc.contributor.authorpl
Skrzat, Janusz - 133416
dc.contributor.authorpl
Kozerska, Magdalena - 104133
dc.contributor.authorpl
Wróbel, Andrzej - 132782
dc.contributor.authorpl
Walocha, Jerzy - 133734
dc.date.accessioned
2015-05-19T08:36:41Z
dc.date.available
2015-05-19T08:36:41Z
dc.date.issuedpl
2014
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.numberpl
4
dc.description.physicalpl
422-428
dc.description.pointspl
15
dc.description.publicationpl
0,5
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
73
dc.identifier.doipl
10.5603/FM.2014.0064
dc.identifier.eissnpl
1644-3284
dc.identifier.issnpl
0015-5659
dc.identifier.projectpl
ROD UJ / P
dc.identifier.uri
http://ruj.uj.edu.pl/xmlui/handle/item/7385
dc.languagepl
eng
dc.language.containerpl
eng
dc.rights*
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa
dc.rights.licence
CC-BY-NC-ND
dc.rights.uri*
http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl
dc.share.type
otwarte czasopismo
dc.source.integrator
false
dc.subject.enpl
bone microarchitecture
dc.subject.enpl
micro-computed tomography
dc.subject.enpl
micro-imaging
dc.subtypepl
Article
dc.titlepl
Three dimensional visualisation and morphometry of bone samples studied in microcomputed tomography (micro-CT)
dc.title.journalpl
Folia Morphologica
dc.typepl
JournalArticle
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
17
Views per month
Views per city
Krakow
3
Ashburn
2
Wroclaw
2
Bayreuth
1
Dublin
1
Philadelphia
1
Sofia
1
Downloads
leszczynski_et-al_three_dimensional_visualisation_2014.pdf
209
leszczynski_et-al_three_dimensional_visualisation_2014.odt
119