Experimental evaluation of ballistic hazards in imaging diagnostic center

2013
journal article
article
5
cris.lastimport.wos2024-04-10T03:24:32Z
dc.abstract.enBackground: Serious hazards for human health and life and devices in close proximity to the magnetic resonance scanners (MRI scanners) include the effects of being hit by ferromagnetic objects attracted by static magnetic field (SMF) produced by scanner magnet - the so-called ballistic hazards classified among indirect electromagnetic hazards. International safety guidelines and technical literature specify different SMF threshold values regarding ballistic hazards - e.g. 3 mT (directive 2004/40/EC, EN 60601-2-33), and 30 mT (BMAS 2009, directive proposal 2011). Investigations presented in this article were performed in order to experimentally verify SMF threshold for ballistic hazards near MRI scanners used in Poland. Material/Methods: Investigations were performed with the use of a laboratory source of SMF (0-30 mT) and MRI scanners of various types. The levels of SMF in which metal objects of various shapes and 0.4-500 g mass are moved by the field influence were investigated. The distance from the MRI scanners (0.2-3T) where hazards may occur were also investigated. Results: Objects investigated under laboratory conditions were moved by SMF of 2.2-15 mT magnetic flux density when they were freely suspended, but were moved by the SMF of 5.6-22 mT when they were placed on a smooth surface. Investigated objects were moved in fields of 3.5-40 mT by MRI scanners. Distances from scanner magnet cover, where ballistic hazards might occur are: up to 0.5 m for 0.2-0.3T scanners; up to 1.3 m for 0.5T scanners; up to 2.0 m for 1.5T scanners and up to 2.5 m for 3T scanners (at the front and back of the magnet). Conclusions: It was shown that SMF of 3 mT magnetic flux density should be taken as the threshold for ballistic hazards. Such level is compatible with SMF limit value regarding occupational safety and health-protected areas/zones, where according to the Polish labor law the procedures of work environment inspection and prevention measures regarding indirect electromagnetic hazards should be applied. Presented results do not support the increase up to 30 mT of the SMF limit for protected area.pl
dc.contributor.authorKarpowicz, Jolantapl
dc.contributor.authorGryz, Krzysztofpl
dc.date.accessioned2017-09-05T06:15:18Z
dc.date.available2017-09-05T06:15:18Z
dc.date.issued2013pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. 37pl
dc.description.number2pl
dc.description.physical31-37pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume78pl
dc.identifier.doi10.12659/PJR.883943pl
dc.identifier.eissn1899-0967pl
dc.identifier.issn1733-134Xpl
dc.identifier.urihttp://ruj.uj.edu.pl/xmlui/handle/item/43802
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 3.0 Polska*
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/pl/legalcode*
dc.share.typeotwarte czasopismo
dc.subject.enmagnetic resonance scannerpl
dc.subject.enstatic magnetic fieldpl
dc.subject.enflying objectspl
dc.subject.enhealth and safety hazardspl
dc.subject.enoccupational safetypl
dc.subtypeArticlepl
dc.titleExperimental evaluation of ballistic hazards in imaging diagnostic centerpl
dc.title.journalPolish Journal of Radiologypl
dc.typeJournalArticlepl
dspace.entity.typePublication
cris.lastimport.wos
2024-04-10T03:24:32Z
dc.abstract.enpl
Background: Serious hazards for human health and life and devices in close proximity to the magnetic resonance scanners (MRI scanners) include the effects of being hit by ferromagnetic objects attracted by static magnetic field (SMF) produced by scanner magnet - the so-called ballistic hazards classified among indirect electromagnetic hazards. International safety guidelines and technical literature specify different SMF threshold values regarding ballistic hazards - e.g. 3 mT (directive 2004/40/EC, EN 60601-2-33), and 30 mT (BMAS 2009, directive proposal 2011). Investigations presented in this article were performed in order to experimentally verify SMF threshold for ballistic hazards near MRI scanners used in Poland. Material/Methods: Investigations were performed with the use of a laboratory source of SMF (0-30 mT) and MRI scanners of various types. The levels of SMF in which metal objects of various shapes and 0.4-500 g mass are moved by the field influence were investigated. The distance from the MRI scanners (0.2-3T) where hazards may occur were also investigated. Results: Objects investigated under laboratory conditions were moved by SMF of 2.2-15 mT magnetic flux density when they were freely suspended, but were moved by the SMF of 5.6-22 mT when they were placed on a smooth surface. Investigated objects were moved in fields of 3.5-40 mT by MRI scanners. Distances from scanner magnet cover, where ballistic hazards might occur are: up to 0.5 m for 0.2-0.3T scanners; up to 1.3 m for 0.5T scanners; up to 2.0 m for 1.5T scanners and up to 2.5 m for 3T scanners (at the front and back of the magnet). Conclusions: It was shown that SMF of 3 mT magnetic flux density should be taken as the threshold for ballistic hazards. Such level is compatible with SMF limit value regarding occupational safety and health-protected areas/zones, where according to the Polish labor law the procedures of work environment inspection and prevention measures regarding indirect electromagnetic hazards should be applied. Presented results do not support the increase up to 30 mT of the SMF limit for protected area.
dc.contributor.authorpl
Karpowicz, Jolanta
dc.contributor.authorpl
Gryz, Krzysztof
dc.date.accessioned
2017-09-05T06:15:18Z
dc.date.available
2017-09-05T06:15:18Z
dc.date.issuedpl
2013
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.additionalpl
Bibliogr. s. 37
dc.description.numberpl
2
dc.description.physicalpl
31-37
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
78
dc.identifier.doipl
10.12659/PJR.883943
dc.identifier.eissnpl
1899-0967
dc.identifier.issnpl
1733-134X
dc.identifier.uri
http://ruj.uj.edu.pl/xmlui/handle/item/43802
dc.languagepl
eng
dc.language.containerpl
eng
dc.rights*
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 3.0 Polska
dc.rights.licence
CC-BY-NC-ND
dc.rights.uri*
http://creativecommons.org/licenses/by-nc-nd/3.0/pl/legalcode
dc.share.type
otwarte czasopismo
dc.subject.enpl
magnetic resonance scanner
dc.subject.enpl
static magnetic field
dc.subject.enpl
flying objects
dc.subject.enpl
health and safety hazards
dc.subject.enpl
occupational safety
dc.subtypepl
Article
dc.titlepl
Experimental evaluation of ballistic hazards in imaging diagnostic center
dc.title.journalpl
Polish Journal of Radiology
dc.typepl
JournalArticle
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
4
Views per month
Views per city
Ashburn
1
San Jose
1
Shanghai
1
Downloads
karpowicz_gryz_experimental_evaluation_of_ballistic_hazards_2013.pdf
37