Comparison of diagnostic accuracy of dual-source CT and conventional angiography in detecting congenital heart diseases

2014
journal article
article
3
cris.lastimport.wos2024-04-10T01:05:17Z
dc.abstract.enBackground: Cardiac dual-source computed tomography (DSCT) is primarily used for coronary arteries. There are limited studies about the application of DSCT for congenital heart diseases. The aim of this study was to determine the diagnostic value of DSCT in the cardiac anomalies. Material and Methods: The images of DSCTs and conventional angiographies of 36 patients (21 male; mean age: 8.5 month) with congenital heart diseases were reviewed and the parameters of diagnostic value of these methods were compared. Cardiac surgery was the gold standard. Results: A total of 105 cardiac anomalies were diagnosed at surgery. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of DSCT were 98.25%, 97.9%, 98.1%, 99.07%, and 98.2%, respectively. The corresponding values of angiography were 95.04%, 98.7%, 97.8%, 98.1%, and 98%, respectively. Only one atrial septal defect (ASD) and two patent ductus arteriosus (PDA) were missed by DSCT. Angiography missed two ASD and two PDA. DSCT also provided important additional findings (n=35) about the intrathoracic or intraabdominal organs. Conclusions: DSCT is a highly accurate diagnostic modality for congenital heart diseases, obviating the need for invasive modalities. Beside its noninvasive nature, the advantage of DSCT over the angiography is its ability to provide detailed anatomical information about the heart, vessels, lungs and intraabdominal organs.pl
dc.contributor.authorSedaghat, Fariborzpl
dc.contributor.authorPouraliakbar, Hamidrezapl
dc.contributor.authorMotevalli, Marziehpl
dc.contributor.authorKarimi, Mohammad Alipl
dc.contributor.authorArmand, Sandbadpl
dc.date.accessioned2017-08-10T08:07:12Z
dc.date.available2017-08-10T08:07:12Z
dc.date.issued2014pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. 168pl
dc.description.physical164-168pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume79pl
dc.identifier.doi10.12659/PJR.890732pl
dc.identifier.eissn1899-0967pl
dc.identifier.issn1733-134Xpl
dc.identifier.urihttp://ruj.uj.edu.pl/xmlui/handle/item/43156
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 3.0 Polska*
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/pl/legalcode*
dc.share.typeotwarte czasopismo
dc.subject.enangiographypl
dc.subject.enheart defectspl
dc.subject.encongenitalpl
dc.subject.enmultidetector computed tomographypl
dc.subtypeArticlepl
dc.titleComparison of diagnostic accuracy of dual-source CT and conventional angiography in detecting congenital heart diseasespl
dc.title.journalPolish Journal of Radiologypl
dc.typeJournalArticlepl
dspace.entity.typePublication
cris.lastimport.wos
2024-04-10T01:05:17Z
dc.abstract.enpl
Background: Cardiac dual-source computed tomography (DSCT) is primarily used for coronary arteries. There are limited studies about the application of DSCT for congenital heart diseases. The aim of this study was to determine the diagnostic value of DSCT in the cardiac anomalies. Material and Methods: The images of DSCTs and conventional angiographies of 36 patients (21 male; mean age: 8.5 month) with congenital heart diseases were reviewed and the parameters of diagnostic value of these methods were compared. Cardiac surgery was the gold standard. Results: A total of 105 cardiac anomalies were diagnosed at surgery. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of DSCT were 98.25%, 97.9%, 98.1%, 99.07%, and 98.2%, respectively. The corresponding values of angiography were 95.04%, 98.7%, 97.8%, 98.1%, and 98%, respectively. Only one atrial septal defect (ASD) and two patent ductus arteriosus (PDA) were missed by DSCT. Angiography missed two ASD and two PDA. DSCT also provided important additional findings (n=35) about the intrathoracic or intraabdominal organs. Conclusions: DSCT is a highly accurate diagnostic modality for congenital heart diseases, obviating the need for invasive modalities. Beside its noninvasive nature, the advantage of DSCT over the angiography is its ability to provide detailed anatomical information about the heart, vessels, lungs and intraabdominal organs.
dc.contributor.authorpl
Sedaghat, Fariborz
dc.contributor.authorpl
Pouraliakbar, Hamidreza
dc.contributor.authorpl
Motevalli, Marzieh
dc.contributor.authorpl
Karimi, Mohammad Ali
dc.contributor.authorpl
Armand, Sandbad
dc.date.accessioned
2017-08-10T08:07:12Z
dc.date.available
2017-08-10T08:07:12Z
dc.date.issuedpl
2014
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.additionalpl
Bibliogr. s. 168
dc.description.physicalpl
164-168
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
79
dc.identifier.doipl
10.12659/PJR.890732
dc.identifier.eissnpl
1899-0967
dc.identifier.issnpl
1733-134X
dc.identifier.uri
http://ruj.uj.edu.pl/xmlui/handle/item/43156
dc.languagepl
eng
dc.language.containerpl
eng
dc.rights*
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 3.0 Polska
dc.rights.licence
CC-BY-NC-ND
dc.rights.uri*
http://creativecommons.org/licenses/by-nc-nd/3.0/pl/legalcode
dc.share.type
otwarte czasopismo
dc.subject.enpl
angiography
dc.subject.enpl
heart defects
dc.subject.enpl
congenital
dc.subject.enpl
multidetector computed tomography
dc.subtypepl
Article
dc.titlepl
Comparison of diagnostic accuracy of dual-source CT and conventional angiography in detecting congenital heart diseases
dc.title.journalpl
Polish Journal of Radiology
dc.typepl
JournalArticle
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
0
Views per month
Downloads
sedaghat_pouraliakbar_motevalli_karimi_armand_comparison_of_diagnostic_accuracy_of_dual-source_ct_2014.pdf
10