A 128-slice CT scanner helpful in localising coronary sinus ostium during CRT-D implantation : case report

2014
journal article
article
cris.lastimport.wos2024-04-09T20:04:09Z
dc.abstract.enBackground: Cardiac resynchronization therapy (CRT) has become a successful treatment option for symptomatic heart failure in patients with poor left ventricular (LV) systolic function and broad QRS complex in the surface electrocardiogram (ECG). Case Report: In this report we present a case of a 70-year-old woman with advanced heart failure due to ischaemic heart disease who underwent an upgrade from VVIR stimulator (pacemaker, PM) to cardiac resynchronization therapy defibrillator (CRT-D). The first attempt was unsuccessful due to problems with inefficient cannulation of the orifice of the coronary sinus (CS). After performing a 3D reconstruction with a 128-slice CT scanner, it was possible to carry out the up-grade to CRT-D resulting in enormous clinical improvement. Conclusions: The case represents an example of the usefulness of 3D reconstruction with the 128-slice CT scanner used after failed CRT-D implantation due to difficulties with efficient cannulation of the coronary sinus orifice in a rare anatomical variant.pl
dc.contributor.authorJaźwiec, Przemysławpl
dc.contributor.authorJagielski, Dariuszpl
dc.contributor.authorGać, Pawełpl
dc.date.accessioned2017-08-08T12:22:24Z
dc.date.available2017-08-08T12:22:24Z
dc.date.issued2014pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. 11pl
dc.description.physical9-11pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume79pl
dc.identifier.doi10.12659/PJR.889859pl
dc.identifier.eissn1899-0967pl
dc.identifier.issn1733-134Xpl
dc.identifier.urihttp://ruj.uj.edu.pl/xmlui/handle/item/43120
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 3.0 Polska*
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/pl/legalcode*
dc.share.typeotwarte czasopismo
dc.subject.encardiac resynchronization therapypl
dc.subject.encardioverter-defibrilator (CRT-D)pl
dc.subject.en128-slice CT scannerpl
dc.subject.encoronary sinuspl
dc.subtypeArticlepl
dc.titleA 128-slice CT scanner helpful in localising coronary sinus ostium during CRT-D implantation : case reportpl
dc.title.journalPolish Journal of Radiologypl
dc.typeJournalArticlepl
dspace.entity.typePublication
cris.lastimport.wos
2024-04-09T20:04:09Z
dc.abstract.enpl
Background: Cardiac resynchronization therapy (CRT) has become a successful treatment option for symptomatic heart failure in patients with poor left ventricular (LV) systolic function and broad QRS complex in the surface electrocardiogram (ECG). Case Report: In this report we present a case of a 70-year-old woman with advanced heart failure due to ischaemic heart disease who underwent an upgrade from VVIR stimulator (pacemaker, PM) to cardiac resynchronization therapy defibrillator (CRT-D). The first attempt was unsuccessful due to problems with inefficient cannulation of the orifice of the coronary sinus (CS). After performing a 3D reconstruction with a 128-slice CT scanner, it was possible to carry out the up-grade to CRT-D resulting in enormous clinical improvement. Conclusions: The case represents an example of the usefulness of 3D reconstruction with the 128-slice CT scanner used after failed CRT-D implantation due to difficulties with efficient cannulation of the coronary sinus orifice in a rare anatomical variant.
dc.contributor.authorpl
Jaźwiec, Przemysław
dc.contributor.authorpl
Jagielski, Dariusz
dc.contributor.authorpl
Gać, Paweł
dc.date.accessioned
2017-08-08T12:22:24Z
dc.date.available
2017-08-08T12:22:24Z
dc.date.issuedpl
2014
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.additionalpl
Bibliogr. s. 11
dc.description.physicalpl
9-11
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
79
dc.identifier.doipl
10.12659/PJR.889859
dc.identifier.eissnpl
1899-0967
dc.identifier.issnpl
1733-134X
dc.identifier.uri
http://ruj.uj.edu.pl/xmlui/handle/item/43120
dc.languagepl
eng
dc.language.containerpl
eng
dc.rights*
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 3.0 Polska
dc.rights.licence
CC-BY-NC-ND
dc.rights.uri*
http://creativecommons.org/licenses/by-nc-nd/3.0/pl/legalcode
dc.share.type
otwarte czasopismo
dc.subject.enpl
cardiac resynchronization therapy
dc.subject.enpl
cardioverter-defibrilator (CRT-D)
dc.subject.enpl
128-slice CT scanner
dc.subject.enpl
coronary sinus
dc.subtypepl
Article
dc.titlepl
A 128-slice CT scanner helpful in localising coronary sinus ostium during CRT-D implantation : case report
dc.title.journalpl
Polish Journal of Radiology
dc.typepl
JournalArticle
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
2
Views per month
Views per city
Ashburn
1
Downloads
jazwiec_jagielski_gac_a_128-slice_ct_scanner_helpful_in_localising_coronary_sinus_ostium_2014.pdf