A comparison of Cobb angle : standing versus supine images of late-onset idiopathic scoliosis

2016
journal article
article
10
dc.abstract.enBACKGROUND: Scoliosis is traditionally evaluated by measuring the Cobb angle in radiograph images taken while the patient is standing. However, low-dose computed tomography (CT) images, which are taken while the patient is in a supine position, provide new opportunities to evaluate scoliosis. Few studies have investigated how the patient's position, standing or supine, affects measurements. The purpose of this study was to compare the Cobb angle in images from patients while standing versus supine. MATERIAL AND METHODS: A total of 128 consecutive patients (97 females and 21 males; mean age 15.5 [11-26] years) with late-onset scoliosis requiring corrective surgery were enrolled. One observer evaluated the type of curve (Lenke classification) and measured the Cobb angle in whole-spine radiography (standing) and scout images from low-dose CT (supine) were taken on the same day. RESULTS: For all primary curves, the mean Cobb angle was 59° (SD 12°) while standing and 48° (SD 12°) while in the supine position, with a mean difference of 11° (SD 5°). The correlation between primary standing and supine images had an r value of 0.899 (95% CI 0.860-0.928) and an intra-class correlation coefficient value of 0.969. The correlation between the difference in standing and supine images from primary and secondary curves had an r value of 0.340 (95% CI 0.177-0.484). CONCLUSIONS: We found a strong correlation between the Cobb angle in images obtained while the patient was standing versus supine for primary and secondary curves. This study is only applicable for patients with severe curves requiring surgical treatment. It enables additional studies based on low-dose CT.pl
dc.contributor.authorVavruch, Ludvigpl
dc.contributor.authorTropp, Hanspl
dc.date.accessioned2017-05-08T17:14:38Z
dc.date.available2017-05-08T17:14:38Z
dc.date.issued2016pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. 275-276pl
dc.description.physical270-276pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume81pl
dc.identifier.doi10.12659/PJR.895949pl
dc.identifier.eissn1899-0967pl
dc.identifier.issn1733-134Xpl
dc.identifier.urihttp://ruj.uj.edu.pl/xmlui/handle/item/40171
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 3.0 Polska*
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/pl/legalcode*
dc.share.typeotwarte czasopismo
dc.subject.enscoliosispl
dc.subject.enspinepl
dc.subject.ensupine positionpl
dc.subtypeArticlepl
dc.titleA comparison of Cobb angle : standing versus supine images of late-onset idiopathic scoliosispl
dc.title.journalPolish Journal of Radiologypl
dc.typeJournalArticlepl
dspace.entity.typePublication
dc.abstract.enpl
BACKGROUND: Scoliosis is traditionally evaluated by measuring the Cobb angle in radiograph images taken while the patient is standing. However, low-dose computed tomography (CT) images, which are taken while the patient is in a supine position, provide new opportunities to evaluate scoliosis. Few studies have investigated how the patient's position, standing or supine, affects measurements. The purpose of this study was to compare the Cobb angle in images from patients while standing versus supine. MATERIAL AND METHODS: A total of 128 consecutive patients (97 females and 21 males; mean age 15.5 [11-26] years) with late-onset scoliosis requiring corrective surgery were enrolled. One observer evaluated the type of curve (Lenke classification) and measured the Cobb angle in whole-spine radiography (standing) and scout images from low-dose CT (supine) were taken on the same day. RESULTS: For all primary curves, the mean Cobb angle was 59° (SD 12°) while standing and 48° (SD 12°) while in the supine position, with a mean difference of 11° (SD 5°). The correlation between primary standing and supine images had an r value of 0.899 (95% CI 0.860-0.928) and an intra-class correlation coefficient value of 0.969. The correlation between the difference in standing and supine images from primary and secondary curves had an r value of 0.340 (95% CI 0.177-0.484). CONCLUSIONS: We found a strong correlation between the Cobb angle in images obtained while the patient was standing versus supine for primary and secondary curves. This study is only applicable for patients with severe curves requiring surgical treatment. It enables additional studies based on low-dose CT.
dc.contributor.authorpl
Vavruch, Ludvig
dc.contributor.authorpl
Tropp, Hans
dc.date.accessioned
2017-05-08T17:14:38Z
dc.date.available
2017-05-08T17:14:38Z
dc.date.issuedpl
2016
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.additionalpl
Bibliogr. s. 275-276
dc.description.physicalpl
270-276
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
81
dc.identifier.doipl
10.12659/PJR.895949
dc.identifier.eissnpl
1899-0967
dc.identifier.issnpl
1733-134X
dc.identifier.uri
http://ruj.uj.edu.pl/xmlui/handle/item/40171
dc.languagepl
eng
dc.language.containerpl
eng
dc.rights*
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 3.0 Polska
dc.rights.licence
CC-BY-NC-ND
dc.rights.uri*
http://creativecommons.org/licenses/by-nc-nd/3.0/pl/legalcode
dc.share.type
otwarte czasopismo
dc.subject.enpl
scoliosis
dc.subject.enpl
spine
dc.subject.enpl
supine position
dc.subtypepl
Article
dc.titlepl
A comparison of Cobb angle : standing versus supine images of late-onset idiopathic scoliosis
dc.title.journalpl
Polish Journal of Radiology
dc.typepl
JournalArticle
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
4
Views per month
Views per city
Ashburn
2
San Jose
1
Downloads
vavruch_tropp_a_comparison_of_cobb_angle_2016.pdf
28