Simple view
Full metadata view
Authors
Statistics
Anatomical evaluation of the pulmonary veins and the left atrium using computed tomography before catheter ablation : reproducibility of measurements
atrial fibrillation
heart atria
multidetector computed tomography
Bibliogr. s. 232
BACKGROUND: Atrial fibrillation (AF) is a common supraventricular arrhythmia. ECG-gated MDCT seems to be currently a method of choice for pre-ablation anatomical mapping due to an excellent resolution and truly isotropic three-dimensional nature. The aim of this study was to establish the between-subject variability and inter-observer reproducibility of anatomical evaluation of the pulmonary veins (PV) and the left atrium (LA) using computed tomography. MATERIAL AND METHODS: A retrospective analysis included 42 patients with AF, who were scheduled for a cardiac CT for ablation planning. Images were assessed by two independent radiologists using a semi-automatic software tool. The left atrium anatomy (volume, AP diameter), anatomy of the pulmonary veins (number, ostia diameters and surface area) were evaluated. The relative between-subject variability and the inter-observer variability of measurements were calculated. RESULTS: The heart rate during scanning ranged from 50 to 133/min. (mean 79.1/min.) and all examinations were of adequate image quality. Accessory pulmonary veins were found in 24% of patients. Between-subject variability of the PV ostial cross-sectional area ranged from 33% to 48%. The variability of the left atrium size was 21% for the diameter and 35% for the volume. The inter-observer agreement for the detection of accessory pulmonary veins was good (κ=0.73; 95% CI, 0.54-0.93). CONCLUSIONS: Between-subject variability of the pulmonary vein ostial cross-sectional area and the left artial volume is substantial. The anatomical assessment of the pulmonary vein ostia and the left atrium size in computed tomography presents a good inter-observer reproducibility.
dc.abstract.en | BACKGROUND: Atrial fibrillation (AF) is a common supraventricular arrhythmia. ECG-gated MDCT seems to be currently a method of choice for pre-ablation anatomical mapping due to an excellent resolution and truly isotropic three-dimensional nature. The aim of this study was to establish the between-subject variability and inter-observer reproducibility of anatomical evaluation of the pulmonary veins (PV) and the left atrium (LA) using computed tomography. MATERIAL AND METHODS: A retrospective analysis included 42 patients with AF, who were scheduled for a cardiac CT for ablation planning. Images were assessed by two independent radiologists using a semi-automatic software tool. The left atrium anatomy (volume, AP diameter), anatomy of the pulmonary veins (number, ostia diameters and surface area) were evaluated. The relative between-subject variability and the inter-observer variability of measurements were calculated. RESULTS: The heart rate during scanning ranged from 50 to 133/min. (mean 79.1/min.) and all examinations were of adequate image quality. Accessory pulmonary veins were found in 24% of patients. Between-subject variability of the PV ostial cross-sectional area ranged from 33% to 48%. The variability of the left atrium size was 21% for the diameter and 35% for the volume. The inter-observer agreement for the detection of accessory pulmonary veins was good (κ=0.73; 95% CI, 0.54-0.93). CONCLUSIONS: Between-subject variability of the pulmonary vein ostial cross-sectional area and the left artial volume is substantial. The anatomical assessment of the pulmonary vein ostia and the left atrium size in computed tomography presents a good inter-observer reproducibility. | pl |
dc.contributor.author | Ratajczak, Przemysław | pl |
dc.contributor.author | Sławińska, Agata | pl |
dc.contributor.author | Martynowska-Rymer, Ida | pl |
dc.contributor.author | Strześniewski, Piotr | pl |
dc.contributor.author | Rusak, Grażyna | pl |
dc.date.accessioned | 2017-05-08T14:18:57Z | |
dc.date.available | 2017-05-08T14:18:57Z | |
dc.date.issued | 2016 | pl |
dc.date.openaccess | 0 | |
dc.description.accesstime | w momencie opublikowania | |
dc.description.additional | Bibliogr. s. 232 | pl |
dc.description.physical | 228-232 | pl |
dc.description.version | ostateczna wersja wydawcy | |
dc.description.volume | 81 | pl |
dc.identifier.doi | 10.12659/PJR.898650 | pl |
dc.identifier.eissn | 1899-0967 | pl |
dc.identifier.issn | 1733-134X | pl |
dc.identifier.uri | http://ruj.uj.edu.pl/xmlui/handle/item/40161 | |
dc.language | eng | pl |
dc.language.container | eng | pl |
dc.rights | Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 3.0 Polska | * |
dc.rights.licence | CC-BY-NC-ND | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/pl/legalcode | * |
dc.share.type | otwarte czasopismo | |
dc.subject.en | atrial fibrillation | pl |
dc.subject.en | heart atria | pl |
dc.subject.en | multidetector computed tomography | pl |
dc.subtype | Article | pl |
dc.title | Anatomical evaluation of the pulmonary veins and the left atrium using computed tomography before catheter ablation : reproducibility of measurements | pl |
dc.title.journal | Polish Journal of Radiology | pl |
dc.type | JournalArticle | pl |
dspace.entity.type | Publication |
* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.
Views
4
Views per month
Views per city
Downloads
Open Access