Simple view
Full metadata view
Authors
Statistics
Gd-EOB-DTPA-enhanced MR imaging of the liver : the effect on T2 relaxation times and apparent diffusion coefficient (ADC)
diffusion magnetic resonance imaging
liver neoplasms
magnetic resonance imaging
Bibliogr. s. 108-109
BACKGROUND: To investigate the effect of gadoxetic acid disodium (Gd-EOB-DTPA) on T2 relaxation times and apparent diffusion coefficient (ADC) values of the liver and focal liver lesions on a 1.5-T system. MATERIAL AND METHODS: Magnetic resonance (MR) studies of 50 patients with 35 liver lesions were retrospectively analyzed. All examinations were performed at 1.5T and included T2-weighted turbo spin-echo (TSE) and diffusion-weighted (DW) images acquired before and after intravenous administration of Gd-EOB-DTPA. To assess the effect of this hepatobiliary contrast agent on T2-weighted TSE images and DW images T2 relaxation times and ADC values of the liver and FLLs were calculated and compared pre- and post-injection. RESULTS: The mean T2 relaxation times of the liver and focal hepatic lesions were lower on enhanced than on unenhanced T2-weighted TSE images (decrease of 2.7% and 3.6% respectively), although these differences were not statistically significant. The mean ADC values of the liver showed statistically significant decrease (of 4.6%) on contrast-enhanced DW images, compared to unenhanced images (P>0.05). The mean ADC value of liver lesions was lower on enhanced than on unenhanced DW images, but this difference (of 2.9%) did not reach statistical significance. CONCLUSIONS: The mean T2 relaxation times of the liver and focal liver lesions as well as the mean ADC values of liver lesions were not significantly different before and after administration of Gd-EOB-DTPA. Therefore, acquisition of T2-weighted and DW images between the dynamic contrast-enhanced examination and hepatobiliary phase is feasible and time-saving.
dc.abstract.en | BACKGROUND: To investigate the effect of gadoxetic acid disodium (Gd-EOB-DTPA) on T2 relaxation times and apparent diffusion coefficient (ADC) values of the liver and focal liver lesions on a 1.5-T system. MATERIAL AND METHODS: Magnetic resonance (MR) studies of 50 patients with 35 liver lesions were retrospectively analyzed. All examinations were performed at 1.5T and included T2-weighted turbo spin-echo (TSE) and diffusion-weighted (DW) images acquired before and after intravenous administration of Gd-EOB-DTPA. To assess the effect of this hepatobiliary contrast agent on T2-weighted TSE images and DW images T2 relaxation times and ADC values of the liver and FLLs were calculated and compared pre- and post-injection. RESULTS: The mean T2 relaxation times of the liver and focal hepatic lesions were lower on enhanced than on unenhanced T2-weighted TSE images (decrease of 2.7% and 3.6% respectively), although these differences were not statistically significant. The mean ADC values of the liver showed statistically significant decrease (of 4.6%) on contrast-enhanced DW images, compared to unenhanced images (P>0.05). The mean ADC value of liver lesions was lower on enhanced than on unenhanced DW images, but this difference (of 2.9%) did not reach statistical significance. CONCLUSIONS: The mean T2 relaxation times of the liver and focal liver lesions as well as the mean ADC values of liver lesions were not significantly different before and after administration of Gd-EOB-DTPA. Therefore, acquisition of T2-weighted and DW images between the dynamic contrast-enhanced examination and hepatobiliary phase is feasible and time-saving. | pl |
dc.contributor.author | Cieszanowski, Andrzej | pl |
dc.contributor.author | Podgórska, Joanna | pl |
dc.contributor.author | Rosiak, Grzegorz | pl |
dc.contributor.author | Maj, Edyta | pl |
dc.contributor.author | Grudziński, Ireneusz P. | pl |
dc.contributor.author | Kaczyński, Bartosz | pl |
dc.contributor.author | Szeszkowski, Wojciech | pl |
dc.contributor.author | Milczarek, Krzysztof | pl |
dc.contributor.author | Rowiński, Olgierd | pl |
dc.date.accessioned | 2017-05-05T09:15:29Z | |
dc.date.available | 2017-05-05T09:15:29Z | |
dc.date.issued | 2016 | pl |
dc.date.openaccess | 0 | |
dc.description.accesstime | w momencie opublikowania | |
dc.description.additional | Bibliogr. s. 108-109 | pl |
dc.description.physical | 103-109 | pl |
dc.description.version | ostateczna wersja wydawcy | |
dc.description.volume | 81 | pl |
dc.identifier.doi | 10.12659/PJR.895701 | pl |
dc.identifier.eissn | 1899-0967 | pl |
dc.identifier.issn | 1733-134X | pl |
dc.identifier.uri | http://ruj.uj.edu.pl/xmlui/handle/item/40018 | |
dc.language | eng | pl |
dc.language.container | eng | pl |
dc.rights | Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 3.0 Polska | * |
dc.rights.licence | CC-BY-NC-ND | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/pl/legalcode | * |
dc.share.type | otwarte czasopismo | |
dc.subject.en | diffusion magnetic resonance imaging | pl |
dc.subject.en | liver neoplasms | pl |
dc.subject.en | magnetic resonance imaging | pl |
dc.subtype | Article | pl |
dc.title | Gd-EOB-DTPA-enhanced MR imaging of the liver : the effect on T2 relaxation times and apparent diffusion coefficient (ADC) | pl |
dc.title.journal | Polish Journal of Radiology | pl |
dc.type | JournalArticle | pl |
dspace.entity.type | Publication |
* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.
Views
3
Views per month
Views per city
Downloads
Open Access