Comparison of image quality, diagnostic accuracy and radiation dose between flash model and retrospective ECG-triggered protocols in dual source computed tomography (DSCT) in congenital heart diseases

2017
journal article
article
6
dc.abstract.enBACKGROUND: Dual source computed tomography (DSCT) plays an important role in the diagnosis of congenital heart diseases (CHD). However, the issue of radiation-related side effects constitutes a wide public concern. The aim of the study was to explore the differences in diagnostic accuracy, radiation dose and image quality between a prospectively ECG - triggered high - pitch spiral acquisition (flash model) and a retrospective ECG-gated protocol of DSCT used for the detection of CHD. MATERIAL AND METHODS: The study included 58 patients with CHD who underwent a DSCT examination, including two groups of 29 patients in each protocol. Then, both subjective and objective image quality, diagnostic accuracy and radiation dose were compared between the two protocols. RESULTS: The image quality and the total as well as partial diagnostic accuracy did not differ significantly between the protocols. The radiation dose in the flash model was obviously lower than that in the retrospective model (P<0.05). CONCLUSIONS: Compared to the retrospective protocol, the flash model can significantly reduce the dose of radiation, while maintaining both diagnostic accuracy and image quality.pl
dc.contributor.authorWang, Rongpl
dc.contributor.authorXu, Xiang-Jiupl
dc.contributor.authorHuang, Gangpl
dc.contributor.authorZhou, Xingpl
dc.contributor.authorZhang, Wen-Wenpl
dc.contributor.authorMa, Ya-Qiongpl
dc.contributor.authorZuo, Xiao-napl
dc.date.accessioned2017-02-28T12:19:22Z
dc.date.available2017-02-28T12:19:22Z
dc.date.issued2017pl
dc.date.openaccess0
dc.description.accesstimew momencie opublikowania
dc.description.additionalBibliogr. s. 119pl
dc.description.physical114-119pl
dc.description.versionostateczna wersja wydawcy
dc.description.volume82pl
dc.identifier.doi10.12659/PJR.899876pl
dc.identifier.eissn1899-0967pl
dc.identifier.issn1733-134Xpl
dc.identifier.urihttp://ruj.uj.edu.pl/xmlui/handle/item/39002
dc.languageengpl
dc.language.containerengpl
dc.rightsUdzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 3.0 Polska*
dc.rights.licenceCC-BY-NC-ND
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/pl/legalcode*
dc.share.typeotwarte czasopismo
dc.subject.enimage enhancementpl
dc.subject.enjervell-lange nielsen syndromepl
dc.subject.enmultidetector computed tomographypl
dc.subject.enradiation dosagepl
dc.subtypeArticlepl
dc.titleComparison of image quality, diagnostic accuracy and radiation dose between flash model and retrospective ECG-triggered protocols in dual source computed tomography (DSCT) in congenital heart diseasespl
dc.title.journalPolish Journal of Radiologypl
dc.typeJournalArticlepl
dspace.entity.typePublication
dc.abstract.enpl
BACKGROUND: Dual source computed tomography (DSCT) plays an important role in the diagnosis of congenital heart diseases (CHD). However, the issue of radiation-related side effects constitutes a wide public concern. The aim of the study was to explore the differences in diagnostic accuracy, radiation dose and image quality between a prospectively ECG - triggered high - pitch spiral acquisition (flash model) and a retrospective ECG-gated protocol of DSCT used for the detection of CHD. MATERIAL AND METHODS: The study included 58 patients with CHD who underwent a DSCT examination, including two groups of 29 patients in each protocol. Then, both subjective and objective image quality, diagnostic accuracy and radiation dose were compared between the two protocols. RESULTS: The image quality and the total as well as partial diagnostic accuracy did not differ significantly between the protocols. The radiation dose in the flash model was obviously lower than that in the retrospective model (P<0.05). CONCLUSIONS: Compared to the retrospective protocol, the flash model can significantly reduce the dose of radiation, while maintaining both diagnostic accuracy and image quality.
dc.contributor.authorpl
Wang, Rong
dc.contributor.authorpl
Xu, Xiang-Jiu
dc.contributor.authorpl
Huang, Gang
dc.contributor.authorpl
Zhou, Xing
dc.contributor.authorpl
Zhang, Wen-Wen
dc.contributor.authorpl
Ma, Ya-Qiong
dc.contributor.authorpl
Zuo, Xiao-na
dc.date.accessioned
2017-02-28T12:19:22Z
dc.date.available
2017-02-28T12:19:22Z
dc.date.issuedpl
2017
dc.date.openaccess
0
dc.description.accesstime
w momencie opublikowania
dc.description.additionalpl
Bibliogr. s. 119
dc.description.physicalpl
114-119
dc.description.version
ostateczna wersja wydawcy
dc.description.volumepl
82
dc.identifier.doipl
10.12659/PJR.899876
dc.identifier.eissnpl
1899-0967
dc.identifier.issnpl
1733-134X
dc.identifier.uri
http://ruj.uj.edu.pl/xmlui/handle/item/39002
dc.languagepl
eng
dc.language.containerpl
eng
dc.rights*
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 3.0 Polska
dc.rights.licence
CC-BY-NC-ND
dc.rights.uri*
http://creativecommons.org/licenses/by-nc-nd/3.0/pl/legalcode
dc.share.type
otwarte czasopismo
dc.subject.enpl
image enhancement
dc.subject.enpl
jervell-lange nielsen syndrome
dc.subject.enpl
multidetector computed tomography
dc.subject.enpl
radiation dosage
dc.subtypepl
Article
dc.titlepl
Comparison of image quality, diagnostic accuracy and radiation dose between flash model and retrospective ECG-triggered protocols in dual source computed tomography (DSCT) in congenital heart diseases
dc.title.journalpl
Polish Journal of Radiology
dc.typepl
JournalArticle
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
0
Views per month
Downloads
wang_xu_huang_zhou_zhang_ma_zuo_comparison_of_image_quality_diagnostic_accuracy_2017.pdf
30