Accuracy budget of the optical atomic clocks at KL FAMO

2016
journal article
article
11
cris.lastimport.wos2024-04-09T21:31:26Z
dc.abstract.enThis paper presents a detailed accuracy budget of two independent strontium optical lattice clocks at the National Laboratory FAMO (KL FAMO) probed with a single shared ultra-narrow laser. The combined instability of the two frequency standards was $7 \times 10^{-17}$ after $10^{5}s$ of averaging.pl
dc.affiliationWydział Fizyki, Astronomii i Informatyki Stosowanej : Instytut Fizyki im. Mariana Smoluchowskiegopl
dc.contributor.authorRadzewicz, Czesławpl
dc.contributor.authorMorzyński, Piotrpl
dc.contributor.authorCygan, Agatapl
dc.contributor.authorLisak, Danielpl
dc.contributor.authorBartoszek-Bober, Dobrosławapl
dc.contributor.authorMasłowski, Piotrpl
dc.contributor.authorAblewski, Piotrpl
dc.contributor.authorZachorowski, Jerzy - 102057 pl
dc.contributor.authorGawlik, Wojciech - 101804 pl
dc.contributor.authorCiuryło, Romanpl
dc.contributor.authorZawada, Michałpl
dc.contributor.authorBober, Marcinpl
dc.date.accessioned2016-09-02T12:37:25Z
dc.date.available2016-09-02T12:37:25Z
dc.date.issued2016pl
dc.description.number8pl
dc.description.volume91pl
dc.identifier.articleid084003pl
dc.identifier.doi10.1088/0031-8949/91/8/084003pl
dc.identifier.eissn1402-4896pl
dc.identifier.issn0031-8949pl
dc.identifier.urihttp://ruj.uj.edu.pl/xmlui/handle/item/30001
dc.languageengpl
dc.language.containerengpl
dc.rightsDodaję tylko opis bibliograficzny*
dc.rights.licencebez licencji
dc.rights.uri*
dc.subtypeArticlepl
dc.titleAccuracy budget of the $^{88}Sr$ optical atomic clocks at KL FAMOpl
dc.title.journalPhysica Scriptapl
dc.typeJournalArticlepl
dspace.entity.typePublication
cris.lastimport.wos
2024-04-09T21:31:26Z
dc.abstract.enpl
This paper presents a detailed accuracy budget of two independent strontium optical lattice clocks at the National Laboratory FAMO (KL FAMO) probed with a single shared ultra-narrow laser. The combined instability of the two frequency standards was $7 \times 10^{-17}$ after $10^{5}s$ of averaging.
dc.affiliationpl
Wydział Fizyki, Astronomii i Informatyki Stosowanej : Instytut Fizyki im. Mariana Smoluchowskiego
dc.contributor.authorpl
Radzewicz, Czesław
dc.contributor.authorpl
Morzyński, Piotr
dc.contributor.authorpl
Cygan, Agata
dc.contributor.authorpl
Lisak, Daniel
dc.contributor.authorpl
Bartoszek-Bober, Dobrosława
dc.contributor.authorpl
Masłowski, Piotr
dc.contributor.authorpl
Ablewski, Piotr
dc.contributor.authorpl
Zachorowski, Jerzy - 102057
dc.contributor.authorpl
Gawlik, Wojciech - 101804
dc.contributor.authorpl
Ciuryło, Roman
dc.contributor.authorpl
Zawada, Michał
dc.contributor.authorpl
Bober, Marcin
dc.date.accessioned
2016-09-02T12:37:25Z
dc.date.available
2016-09-02T12:37:25Z
dc.date.issuedpl
2016
dc.description.numberpl
8
dc.description.volumepl
91
dc.identifier.articleidpl
084003
dc.identifier.doipl
10.1088/0031-8949/91/8/084003
dc.identifier.eissnpl
1402-4896
dc.identifier.issnpl
0031-8949
dc.identifier.uri
http://ruj.uj.edu.pl/xmlui/handle/item/30001
dc.languagepl
eng
dc.language.containerpl
eng
dc.rights*
Dodaję tylko opis bibliograficzny
dc.rights.licence
bez licencji
dc.rights.uri*
dc.subtypepl
Article
dc.titlepl
Accuracy budget of the $^{88}Sr$ optical atomic clocks at KL FAMO
dc.title.journalpl
Physica Scripta
dc.typepl
JournalArticle
dspace.entity.type
Publication
Affiliations

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
1
Views per month

No access

No Thumbnail Available