Simple view
Full metadata view
Authors
Statistics
Silver nanowire array sensor for sensitive and rapid detection of
silver
nanowires
hydrogen peroxide
sensor
Na publikacji autorka Kurowska-Tabor Elżbieta podpisana jako Kurowska Elżbieta.
A novel amperometric sensor based on silver nanowire (Ag NW) array was fabricated and used for a rapid and sensitive detection of hydrogen peroxide (H2O2). The 50-nm in diameter nanowires were synthesized by electrodeposition of silver in the nanopores of anodic aluminum oxide (AAO) template. At an applied potential of −0.2 V vs. SCE, the developed Ag NW array electrode exhibited electrocatalytic response toward the reduction of H2O2 at a very wide range of H2O2 concentrations and three significantly linear sections in a calibration plot were observed. The determination of H2O2 with the highest sensitivity of about 0.0266 μA cm−2 μM−1 is possible in the concentration range from 0.1 mM to 3.1 mM with a detection limit of 29.2 μM. Moreover, the proposed sensor exhibited relatively high sensibility, good reproducibility, and satisfying long-term stability. The developed Ag NW array sensor excluded the interference from substances typically present in the biological samples such as ascorbic acid (AA), uric acid (UA), ethanol (EtOH), glucose (G) and oxalate ions.
cris.lastimport.wos | 2024-04-10T02:40:45Z | |
dc.abstract.en | A novel amperometric sensor based on silver nanowire (Ag NW) array was fabricated and used for a rapid and sensitive detection of hydrogen peroxide (H2O2). The 50-nm in diameter nanowires were synthesized by electrodeposition of silver in the nanopores of anodic aluminum oxide (AAO) template. At an applied potential of −0.2 V vs. SCE, the developed Ag NW array electrode exhibited electrocatalytic response toward the reduction of H2O2 at a very wide range of H2O2 concentrations and three significantly linear sections in a calibration plot were observed. The determination of H2O2 with the highest sensitivity of about 0.0266 μA cm−2 μM−1 is possible in the concentration range from 0.1 mM to 3.1 mM with a detection limit of 29.2 μM. Moreover, the proposed sensor exhibited relatively high sensibility, good reproducibility, and satisfying long-term stability. The developed Ag NW array sensor excluded the interference from substances typically present in the biological samples such as ascorbic acid (AA), uric acid (UA), ethanol (EtOH), glucose (G) and oxalate ions. | pl |
dc.affiliation | Wydział Chemii : Zakład Chemii Fizycznej i Elektrochemii | pl |
dc.contributor.author | Kurowska-Tabor, Elżbieta - 115284 | pl |
dc.contributor.author | Brzózka, Agnieszka - 123610 | pl |
dc.contributor.author | Sulka, Grzegorz - 132161 | pl |
dc.contributor.author | Jaskuła, Marian - 128495 | pl |
dc.contributor.author | Jarosz, Magdalena - 116468 | pl |
dc.date.accessioned | 2015-01-23T08:31:13Z | |
dc.date.available | 2015-01-23T08:31:13Z | |
dc.date.issued | 2013 | pl |
dc.description.additional | Na publikacji autorka Kurowska-Tabor Elżbieta podpisana jako Kurowska Elżbieta. | pl |
dc.description.admin | [AU] Brzózka, Agnieszka [SAP14008973] | pl |
dc.description.physical | 439-447 | pl |
dc.description.points | 35 | pl |
dc.description.volume | 104 | pl |
dc.identifier.doi | 10.1016/j.electacta.2013.01.077 | pl |
dc.identifier.eissn | 1873-3859 | pl |
dc.identifier.issn | 0013-4686 | pl |
dc.identifier.uri | http://ruj.uj.edu.pl/xmlui/handle/item/2685 | |
dc.language | eng | pl |
dc.language.container | eng | pl |
dc.rights.licence | bez licencji | |
dc.subject.en | silver | pl |
dc.subject.en | nanowires | pl |
dc.subject.en | hydrogen peroxide | pl |
dc.subject.en | sensor | pl |
dc.subtype | Article | pl |
dc.title | Silver nanowire array sensor for sensitive and rapid detection of $H_2O_2$ | pl |
dc.title.journal | Electrochimica Acta | pl |
dc.type | JournalArticle | pl |
dspace.entity.type | Publication |