Improvement of copper FAAS determination conditions via preconcentration procedure with the use of salicylaldoxime complex trapped in polymer matrix

2012
journal article
article
cris.lastimport.scopus2024-04-07T17:23:22Z
dc.abstract.enThe paper presents application of a new resin dedicated to copper(II) flow-injection on-line preconcentration prior its flame atomic absorption spectrometric (FAAS) determination. The new sorbent, obtained by suspension polymerization technique, was styrene-divinylbenzene copolymer modified with 5-dodecylsalicylaldoxime-copper(II) complex. In flow mode leaching of initially imprinted Cu(II) ions from polymer beads was effective with 1% (v/v) nitric acid, however for elution of ions retained on the sorbent during the loading process sufficient efficiency was obtained for 0.5% (v/v) nitric acid. The most effective copper(II) sorption was observed within sample pH ca. 6.3 at flow rate 7.5 mLmin$^{-1}$. Furthermore, preconcentration studies of Cu(II) ions realized in the presence of popular foreign ions like Cd(II), Pb(II), Zn(II), Ni(II), Mn(II), Co(II) did not reveal significant interference. The expected effect of Cu(II)-imprinting was confirmed by higher tolerance level for interferents ions concentration for the new sorbent than for the control polymer. It was found that alkaline metals ions and humic acid had the most relevant influence on copper(II) uptake. Accuracy of the evaluated method was assessed for anal- ysis of water samples (tap and mineral water, river water, artesian water) and certified water reference materials compare them to results obtained by inductively plasma mass spectrometry. The satisfactory relative error values obtained with use of standard addition calibration method, confirms the feasibility of this method for Cu(II) determination in water samples. Application of 120s sorption time enabled to obtain 74-fold enrichment factor and limit of detection (3$\sigma$) equal to 0.4$\mu$gL$^{-1}$.pl
dc.affiliationWydział Chemii : Zakład Chemii Analitycznejpl
dc.contributor.authorTelk, Anna - 156141 pl
dc.contributor.authorWalas, Stanisław - 132508 pl
dc.contributor.authorLandowska, Lucynapl
dc.contributor.authorKonefał-Góral, Jadwigapl
dc.date.accessioned2015-09-03T11:38:17Z
dc.date.available2015-09-03T11:38:17Z
dc.date.issued2012pl
dc.description.additionalNa publikacji autorka Telk Anna podpisana jako Tobiasz Anna.pl
dc.description.physical82-88pl
dc.description.points40pl
dc.description.volume96pl
dc.identifier.doi10.1016/j.talanta.2012.02.005pl
dc.identifier.eissn1873-3573pl
dc.identifier.issn0039-9140pl
dc.identifier.urihttp://ruj.uj.edu.pl/xmlui/handle/item/15331
dc.languageengpl
dc.language.containerengpl
dc.rightsDodaję tylko opis bibliograficzny*
dc.rights.licencebez licencji
dc.rights.uri*
dc.subject.enhydrooximepl
dc.subject.enion imprinted polymerpl
dc.subject.enpreconcentrationpl
dc.subject.encopper determinationpl
dc.subject.enFI-FAASpl
dc.subject.enLIX 622 ®pl
dc.subtypeArticlepl
dc.titleImprovement of copper FAAS determination conditions via preconcentration procedure with the use of salicylaldoxime complex trapped in polymer matrixpl
dc.title.journalTalantapl
dc.title.volumeSelected Papers presented at the 17th ICFIA, Krakow, Poland (2011)pl
dc.typeJournalArticlepl
dspace.entity.typePublication

* The migration of download and view statistics prior to the date of April 8, 2024 is in progress.

Views
0
Views per month

No access