W dniach od 2 kwietnia do 5 kwietnia 2024 r. prowadzone będą prace związane z wdrożeniem nowej wersji systemu Repozytorium UJ. Nie będzie możliwe wprowadzanie nowych informacji do repozytorium. Za utrudnienia przepraszamy.
Preparation of a new Cd(II)-imprinted polymer and its application to determination of cadmium(II) via flow-injection-flame atomic absorption spectrometry
Preparation of a new Cd(II)-imprinted polymer and its application to determination of cadmium(II) via flow-injection-flame atomic absorption spectrometry
Preparation of a new Cd(II)-imprinted polymer and its application to determination of cadmium(II) via flow-injection-flame atomic absorption spectrometry
pl
dc.type
JournalArticle
pl
dc.description.physical
1305-1310
pl
dc.description.additional
Na publikacji autorka Telk Anna podpisana jako Tobiasz Anna.
pl
dc.abstract.en
A new cadmium(II)-imprinted polymer based on cadmium(II) 2,2'-{ethane-1,2-diylbis[nitrilo(E)methylylidene]}
diphenolate-4-vinylpyridine complex was obtained via suspension
polymerization. The beads were used as a minicolumn packing for flow-injection-flame atomic absorp-
tion spectrometry (FI-FAAS) determination of cadmium(II) in water samples. Sorption effectiveness was
optimal within pH range of 6.6-7.7. Nitric acid, 0.5% (v/v) was used as eluent. Fast cadmium(II) sorption
by the proposed material enabled to apply sample flow rates up to 10mLmin$^{-1}$
without loss in sorption
effectiveness. Enrichment factor (EF), concentration efficiency (CE) and limit of detection (LOD, $3\sigma$)
found for 120-s sorption time were 117, 39.1min$^{-1}$
and 0.11 $\mu$gL$^{-1}$, respectively. Sorbent stability was
proved for at least 100 preconcentration cycles (RSD=2.9%). When compared to non-imprinted polymer
the new Cd(II)-imprinted polymer exhibited improved selectivity towards cadmium(II) against other
heavy metal ions, especially Cu(II) and Pb(II), as well as light metal ions. Accuracy of the method was
tested for ground water and waste water certified reference materials and fortified water. The method
was applied to Cd(II) determination in natural water samples.
pl
dc.description.volume
80
pl
dc.description.number
3
pl
dc.description.points
32
pl
dc.identifier.doi
10.1016/j.talanta.2009.09.021
pl
dc.identifier.eissn
1873-3573
pl
dc.title.journal
Talanta
pl
dc.language.container
eng
pl
dc.affiliation
Wydział Chemii : Zakład Technologii Chemicznej
pl
dc.affiliation
Wydział Chemii : Zakład Chemii Analitycznej
pl
dc.affiliation
Wydział Chemii : Zakład Chemii Organicznej
pl
dc.subtype
Article
pl
dc.rights.original
bez licencji
pl
.pointsMNiSW
[2010 A]: 32
Pliki tej pozycji
Plik
Rozmiar
Format
Przeglądanie
Nie ma plików powiązanych z tą pozycją.
Pozycja umieszczona jest w następujących kolekcjach